05 general information, 05 general information -3, Ultrafeed va 4000s – Tweco VA 4000S Ultra-Feed User Manual
Page 21
ULTRAFEED VA 4000S
Manual No. 0-5135
2-3
INTRODUCTION
Input Voltage:
115 VAC
Input Frequency:
50/60 Hz
Input Voltage Tolerance
±10%
Maximum Input Current
4.0 Amps
Wire Sizes
0.024 - 1/8" / 0.6 - 3.2
Maximum Wire
Coil/Spool Weight
60 lb. / 27 kg
Feed Rolls
4 (All Driven)
Welding Current (I)
500 A @ 100%
Welding Gun/Torch Size
Tweco #4 Std
Maximum Shielding Gas
Inlet Pressure
100 P.S.I. / 6.9 Bar
Weight (Less Wire)
35 lbs. / 15.9 kg
VA4000S
Weight (Less Wire)
28 lbs. / 12.7 kg
Separation Unit
Approvals
NEMA EW 3
IEC 60974-1
Wire Speed Range
for All Filler Wire Sizes
50 - 875 IPM
1.25 - 22.1 MPM
UltraFeed VA 4000S Specifications
Table 2-1: Product Specifications
S
S
S
Art # A-09220
Figure 2-1: Ultrafeed VA 4000S Front View
2.05 General Information
The ULTRAFEED VA 4000S is a semiautomatic, solid state
controller and Separation wire feeder capable of a 100%
duty cycle. The system offers both load and line voltage
compensation helping to maintain a constant wire feed
speed, even with changes in the input voltage and/or load.
The ULTRAFEED VA 4000S sheet metal box totally
encloses the solid state control circuitry. A hinged, latched
feedhead cover allows quick and easy access to the
feedhead featuring quick change feed rolls, and tool-less
knobs and clamps for changeover of guides and guns.
The ULTRAFEED VA 4000S comes with an abundance of
standard features including:
• an on/off rocker switch
• a circuit breaker for total system protection
• a wire feed speed control
• a power source voltage control
• an inch switch
• a gas purge switch
• a 2 step / 4 step selector switch
• PC board adjustments for enhanced runin control
• a solid state electronic brake for dynamic braking
• four quick change, gear-driven feed rolls
• a gas valve solenoid
• a low voltage gun trigger circuit for operator safety
• a variety of add-on options to configure the unit for
any wire-welding situation.
The ULTRAFEED VA 4000S has been designed to comply
with CSA NRTL/C, NEMA EW 3, and IEC 60974-1
standards.