05 machine specifications, 05 machine specifications -3 – Tweco 180 Portable MIG User Manual
Page 19

INTRODUCTION
FABRICATOR 140, 180
July 20, 2007
2-3
Manual 0-4991
2.05 Machine Specifications
Description
Fabricator 140
Fabricator 180
Package System Part Number
W1002500
W1002600
Power Source Weight
64 lb (29 kg)
80 lb (36 kg)
Power Source Dimensions HxWxD
Number of Phases
Frequency
Flexible Supply Cable Size
7 ft (2.3 m) 14AWG
8 ft (2.5 m) 12AWG
Supply Lead Plug Type
5-15P
6-50P
Nominal Input Voltage
120V AC
230V AC
Rated Input Current
^ 15A
^ 21A
Rated kVA @ 100% Duty Cycle
1kVA
1.9kVA
Rated Input Current
15A (65A@40%)
21A
(130A@25%)
Maximum Input Current
24A (90A@20%)
31A (180A@15%)
Generator Requirements
# 6kVA
# 8.5kVA
Supply VA @ max. output
# 5.1kVA
# 7kVA
Open Circuit Voltage Range
20.5 – 34V
19.5 – 38V
Output Current Range
30 – 140A
30 – 180A
Duty Cycle Period
Number of Output Voltage Values
4
6
Minimum Mains Circuit to suit factory fitted Plug
& Lead (Weld Current @ Duty Cycle)
(+) 15A (65A@40%)
(+) 21A (130A@25%)
Maximum Mains Circuit to suit factory fitted Plug
& Lead (Weld Current @ Duty Cycle)
(+) 24A (90A@20%)
(+) 31A (180A@15%)
Wire Size Range
Steel
Stainless Steel
.023” - .030”
(0.6 - 0.8mm)
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
Flux Core
.030” - .035”
(0.8 - 0.9mm)
.030” - .035” - .045"
(0.8 - 0.9 - 1.2mm)
Aluminum
.030” - .035” (0.8 - 0.9mm)
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
15.8 x 10.0 x 21.3”
400 x 255 x 540mm
1 Ø
10 Minutes
60Hz
^ The Rated Input Current should be used for the determination of cable size & supply requirements.
+ Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements for
your situation in this regard.
# Generator Requirements at the Maximum Output Duty Cycle.
Table 2-1: Specifications