E83 error code displayed
No weld current is available.
CPU checks mains supply (input)
voltage when the on/off switch on
rear panel of machine is turned ON.
Buzzer sounds constantly.
Switch machine off then on to reset
E83 error.
E93 error code displayed
Weld current ceases.
Memory chip (EEPROM) on control
PCB can not read/write weld
parameters
Buzzer sounds constantly.
Switch machine off.
E94 error code displayed
Weld current ceases.
Temperature sensor TH1 for IGBTs
or sensor TH2 for secondary diodes
are open circuit
Buzzer sounds constantly.
Switch machine off.
E99 error code displayed
A
M
ain on/off switch on machine has been
turned off
A
Turn on/off switch on.
Weld current ceases.
Mains supply (input) voltage has
been turned off but control circuit
has power from the primary
capacitors
B
M
ains supply (input) voltage has been
turned off
B
Have an Accredited Thermal Arc
Service Agent or a qualified electrician
check the Mains voltage and fuses
Buzzer sounds constantly.
Must switch machine off then on to
reset E99 error.
The Welding Power Source’s
temperature sensors have
malfunctioned.
Have an Accredited Thermal Arc
Service Agent check or replace the
temperature sensors.
Memory chip (EEPROM) error
Have an Accredited Thermal Arc
Service Agent check the control PCB
The Primary supply (input) voltage
fluctuates and is not stable.
Have an Accredited Thermal Arc
Service Agent check connector plug on
input PCB and the Mains voltage
9
10
11
12