Arcmaster, 300 s – Tweco 300 S Arcmaster User Manual
Page 47
![background image](/manuals/595258/47/background.png)
ARCMASTER
®
300 S
March 31, 2006
12-1
SECTION 12:
POWER SOURCE ERROR CODES
sk
r
a
m
e
R
y
d
e
m
e
R
es
u
a
C
el
bi
ss
o
P
n
oit
pi
rc
s
e
D
E01 error code displayed
A
The Welding Power Source’s duty cycle
has been exceeded.
A
Let Power Source cool down then keep
within its duty cycle.
Weld current ceases.
Temperature sensor TH1 (protects
IGBTs) is greater than 80ºC for
B
Fan ceases to operate.
B
Have an Accredited Thermal Arc
Service Agent investigate
Buzzer sounds constantly.
C
Air flow is restricted by vents being
blocked
C
Unblock vents then let Power Source
cool down.
Fan operates at max speed.
E01 resets when TH1 decreases to
70ºC for about 30 seconds.
E02 error code displayed
A
The Welding Power Source’s duty cycle
has been exceeded.
A
Let Power Source cool down then keep
within its duty cycle.
Weld current ceases.
Temperature sensor TH2 (protects
secondary diodes) is greater than
80ºC for about 1 second
B
Fan ceases to operate.
B
Have an Accredited Thermal Arc
Service Agent investigate
Buzzer sounds constantly.
C
Air flow is restricted by vents being
blocked
C
Unblock vents then let Power Source
cool down.
Fan operates at max speed.
E02 resets when TH1 decreases to
70ºC for about 30 seconds.
E03 error code displayed
A
Primary current is too high because
welding arc is too long.
A
Reduce length of welding arc.
Weld current ceases.
Primary (input) current too high
B
Mains supply voltage is more than 10%
below nominal voltage
B
Have an Accredited Thermal Arc
Service Agent or a qualified electrician
check for low Mains voltage.
Buzzer sounds constantly.
Switch machine off then on to reset
E03 error.
E11 error code displayed
Weld current ceases.
Over Primary supply (input) voltage
at primary capacitors is exceeded
for one second
Buzzer sounds constantly.
Error code E11 automatically will
reset when the voltage reduces.
Primary supply voltage is greater than
the nominal voltage plus 10%
Have an Accredited Thermal Arc
Service Agent or a qualified electrician
check the Primary voltage.
1
2
3
4