SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This
conformity shall be checked by qualified personnel.

Input

Power Input

Current

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

46

130

160

#1

230

50/60

49

125

150

#1

380

50/60

52

81

100

#4

400 (CE)

50/60

52

77

90

#4

460

50/60

59

75

90

#4

600

50/60

52

51

60

#6

* Suggested wire size based on United States NFPA 70 National Electrical Code 2005 edition
published by the National Fire Prevention Association.
Listings are from rable 400.5(B) for flexible cord of certain types rated for 75 deg. C in ambient
temperatures up to 30 deg. C. Using wires of lower temperature rating or different insulation
type may require larger wire size. Derate for higher ambient temperature.
Wire sizes are suggestions only. Always refer to your local and national codes that apply to
your location for correct wire sizes.

Ultra-Cut 200 Power Supply Electrical Inputs

Suggested Sizes (See Note)

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type
and method of wire being used.

Gas Supply

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure
regulators must be double-stage and installed as close as possible to the gas console. Contaminated gas
can cause one or more of the following problems:

Reduced cutting speed

Poor cut quality

Poor cutting precision

Reduced consumables life.

Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.