02 leads and cables, 02 leads and cables -2 – Tweco 300 Auto-Cut User Manual
Page 92
Manual No. 0-4817 Auto-Cut 300
6-2
Parts List
6.02 Leads and Cables
Refer to section 3.05 for ground connections and ground cables.
Work Cable
O
Primary power
Work
Torch
Auto-Cut 300
Power Supply
Arc Starter /
Gas Control Module
(GCM-1000)
Pilot Return
Negative
Coolant Supply
Coolant Return
Control Cable
CNC
CNC Cable
Positioning
Tube
Control
Cable
Ground
Cable
P
A
B
C
D
E
K
G: Torch Lead Set, Shielded
- Coolant Supply w/ Negative
- Coolant Return
- Pilot Return
- Plasma Gas
- Shield Gas
F
Art # A-09950
NOTE :
Supply lead set includes Pilot Return Cable, Negative Cable, Coolant Supply & Return Hoses, and Control
Cable.
Key
Description
3 ft
1 m
10 ft
3.05 m
15 ft
4.5 m
25 ft
7.6 m
35 ft
10.6 m
50 ft
15.2 m
75 ft
22.8 m
100 ft
30.5 m
125 ft
38.1 m
A,B,C,D,E Supply Lead Set
4-3096 4-3097 4-3098 4-3099 4-3100 4-3101 4-3102 4-3103 4-3104
A
Pilot Return Cable (only) (4 ft / 1.2 m)
9-4890
B
Negative Cable (only)
9-4892
C
Hose, Coolant Supply (only)
9-4886
D
Hose, Coolant Return (only)
9-4888
E
Control Cable (only), Power Supply
to Arc Starter (4 ft / 1.2 m)
9-4941
F
Ground Wire (only), Power Supply to
Gas Control Module, , 4 ft / 1.2 m
9-4923
F1
Ground Cable, Gas Control Module
to Earth
9-4923
9-4924 9-4925
9-4926 9-4927 9-4928 9-4929
G
Torch Lead Assembly
4-3044 4-3045 4-3046
K
Control Cable, Power Supply
to Gas Control Module
9-9331
O
Work Cable
9-0449 9-0450 9-0451 9-0452 9-0453 9-0454 9-0455 9-0456
P
Control Cable, CNC
to Power Supply
9-8312
9-8313 9-8315 9-8316 9-8317
Leads Length
Leads Catalog Numbers; Auto-Cut 300 Power Supply, XT-301 Torch