03 primary input power connections, Cutmaster 42 – Tweco 42 CutMaster Operating Manual User Manual
Page 16
CUTMASTER 42
CUTMASTER 42
INSTALLATION 3-2 Manual 0-5141
Manual 0-5141
3-3 INSTALLATION
3.03 Primary Input Power Connections
Power Cords Included With Power Supply
Attached to the power supply is an input power cord with a 230 Volt 50 Amp NEMA 6-50P for plug. Supplied adapters allow for
connection of the power supply input cable plug when using 120V input power.
Art# A-09432_AB
Figure 3-1: 120VAC Adapter Pigtail
CAUTION
Check your power source for correct voltage before plugging in or connecting the unit. The primary
power source, fuse, and any extension cords used must conform to local electrical code and the rec-
ommended circuit protection and wiring requirements as specified in Section 2.
Input Voltage (VAC)
Rated Output
Amps (RMS) input at rated
output, 60 Hz, single-phase
kVA
120V, 15A Circuit
20A, 88V
20.4
2.5
120V, 20A Circuit
27A, 91V
28.5
3.5
120V, 30A Circuit
27A, 91V
28.5
3.5
208-230V, 20A Circuit
40A, 96V
23-21.4
4.8
3.04 Air Supply Connections
A. Connecting Air Supply to Unit
The connection is the same for compressed air or industrial compressed air in gas cylinders.
1. Connect the gas line to the compressed air inlet port at the appropriate pressure.
Art# A-09337
Air Inlet
On/Off
Switch
Figure 3-2: Gas Connection to Compressed Air input
B. Using Industrial Compressed Air In Gas Cylinders
When using Industrial compressed air in gas cylinders as the gas supply:
1. Refer to the manufacturer’s specifications for installation and maintenance procedures for high pressure gas regulators.
2. Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign material. Briefly open each
cylinder valve to blow out any dust which may be present.
3. The cylinder must be equipped with an adjustable high - pressure regulator capable of outlet pressures up to 100 psi
(6.9 bar) maximum and flows of at least 250 scfh (120 lpm).
4. Connect gas supply hose to the cylinder.
NOTE
Pressure should be set at 100 psi (6.9 bar) at the high pressure gas cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm) I.D.
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions.
Do Not use Teflon tape as a thread sealer, as small particles of the tape may break off and block the
small gas passages in the torch.