3. Loosen the two bolts on the top of the Filter Assembly

enough to allow the Filter Elements to move freely.

4. Note the location and orientation of the old Filter Ele-

ments.

5. Slide out the old Filter Elements.

First & Second

Stage

Cartridges

(as marked)

Art # A-02942

Optional Two-Stage Filter Replacement

6. Slide the replacement Filter Elements into the Filter

Assembly, with the same orientation as noted in Step

4 above.

7. Hand tighten the two bolts evenly, then torque each

bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper torque

may damage the gasket.

8. Slowly apply air pressure to the assembly, checking

for leaks.

NOTE

A small amount of air leakage from the bottom

fitting is normal.

This completes the parts replacement procedures.