05 input wiring specifications, Input wiring specifications -3 – Tweco CutMaster 12mm-20mm-25mm User Manual
Page 17
CUTMASTER 12mm, 20mm, 25mm
Manual 0-5117 2-3 INTRODUCTION
22.5"
0.57 m
43 lb / 19.5 kg
10.75"
273 mm
16.375"
416 mm
Art # A-07941
6"
150 mm
24"
610 mm
6"
150 mm
6"
150 mm
Art # A-07925_AB
Power Supply Dimensions & Weight Ventilation Clearance Requirements
2.05 Input Wiring Specifications
CutMaster 12mm Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I eff
Fuse (amps)
Flexible Cord
(AWG)
3 Phase
380
50/60
5.3
8
5
10
16
400
50/60
5.3
8
5
10
16
CutMaster 20mm Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I eff
Fuse (amps)
Flexible Cord
(AWG)
3 Phase
380
50/60
11
16
11
20
14
400
50/60
11
16
11
20
14
CutMaster 25mm Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I eff
Fuse (amps)
Flexible Cord
(AWG)
3 Phase
380
50/60
11.8
18
12
20
14
400
50/60
11.8
17
11
20
14
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.