04 power supply specifications, Power supply specifications -2 – Tweco CutMaster 12mm-20mm-25mm User Manual
Page 16
CUTMASTER 12mm, 20mm, 25mm
INTRODUCTION 2-2 Manual 0-5117
2.04 Power Supply Specifications
12mm
20mm
25mm
Input Power
380 VAC (360 - 440 VAC),
Three Phase, 50/60Hz
380 VAC (360 - 440 VAC),
Three Phase, 50/60Hz
380 VAC (360 - 440 VAC),
Three Phase. 50/60 Hz
400 VAC (360 - 440 VAC),
Three Phase, 50/60 Hz
400 VAC (360 - 440 VAC),
Three Phase, 50/60 Hz
400 VAC (360 - 440 VAC),
Three Phase, 50/60 Hz
† NOTE: Some CutMaster 12mm models will only operate on 380-400V. Please check your
machine before attempting to run on any of the other voltages that are listed above.
Input Power Cable
•
Power Supply includes
input cable.
•
Cable for 400V 3 Phase.
•
Power supply includes input
cable
•
Cable for 400V 3 Phase.
•
Power Supply includes input
power cable.
•
Cable for 400V 3 Phase
•
For cables at other input
voltages see section 2.05
Output Current
20 - 40 Amps,
Continuously Adjustable
20 - 60 Amps,
Continuously Adjustable
20 - 80 Amps,
Continuously Adjustable
Power Supply Gas
Filtering Ability
Particulates to 5 Microns
Particulates to 5 Microns
Particulates to 5 Microns
Ambient
Temperature
Duty Cycle Ratings
@ 40° C (104° F)
Operating Range 0° - 50° C
Duty Cycle Ratings
@ 40° C (104° F)
Operating Range 0° - 50° C
Duty Cycle Ratings
@ 40° C (104° F)
Operating Range 0° - 50° C
CUTMASTER 12mm Power Supply Duty Cycle *
IEC Rating
All
Units
Duty Cycle
40%
60%
100%
Current
40 Amps
35 Amps
25 Amps
DC Voltage
96
93
90
CUTMASTER 20mm Power Supply Duty Cycle *
IEC Rating
All
Units
Duty Cycle
40%
60%
100%
Current
60 Amps
50 Amps
30 Amps
DC Voltage
104
102
100
CUTMASTER 25mm Power Supply Duty Cycle *
IEC Rating
All
Units
Duty Cycle
40%
60%
100%
Current
80 Amps
60 Amps
55 Amps
DC Voltage
112
106
102
NOTE
IEC Rating is determined as specified by the International Electro-Technical Commission. These specifica-
tions include calculating an output voltage based upon power supply rated current. To facilitate comparison
between power supplies, all manufacturers use this output voltage to determine duty cycle.