tekmar 033 4 Timer User Manual
Page 2
![background image](/manuals/594586/2/background.png)
© 2007
D 033 - 10/07
2 of 12
Table of Contents
Table of Contents ............................................................2
Display and Switch Settings ...........................................2
Switch
Settings
.......................................................2
Access
Levels
.........................................................2
Display and Symbols Description............................3
User
Interface
.........................................................3
Setup ..............................................................................4
Time
Menu
..............................................................4
Schedule
Menu
.......................................................6
Miscellaneous Menu ..............................................9
Timer Operation .............................................................9
Time
Clock
............................................................ 10
Setting the Schedule ............................................ 10
Programming the Relay ........................................ 11
Backlight
............................................................... 11
Error Messages ............................................................ 11
Cleaning the Timer ...................................................... 12
Warranty ....................................................................... 12
Display and Switch Settings
Switch Settings
Access Levels
Lock/Unlock (Switch #1)
Use the Lock/Unlock switch to lock or unlock the Access
Level of the 033.
To unlock the Access Level, set the switch to the unlocked
(Off) position.
To lock the Access Level, set the switch to the locked
(On) position. Once locked, the padlock shows in the
bottom right corner of the display except when viewing
the current time or date.
Relay NO / Relay NC (Switch #2)
The Relay NO / Relay NC switch is used to change the
relay from normally open to normally closed. The user can
decide how they want the relay to operate in their specific
application. Note: The relay will always be OPEN when
there is no power present at the device.
•
•
•
The Access Level restricts the number of Menus, Items
and Adjustments that can be accessed by the user. The
Access Level setting is found in the Miscellaneous (MISC)
menu. Select the appropriate access level for the people
who work with the Timer on a regular basis.
The 033 has three Access Levels:
Advanced (ADV): access to all settings
User (USER): for property owners
Limited (LTD): limited temperature adjustment
For more information, see the Misc (Miscellaneous) Menu
section.
•
•
•
In the following menu tables, the access level the item is
visible in is shown in the access column.
To adjust the Access Level:
1. Set the Unlock / Lock switch to the unlock position.
If a tN4 System Control is connected to the 033, the
Unlock / Lock switch on the tN4 System Control must
be set to the unlock position.
2. Use the Menu button to select the Misc menu.
3. Use the Item button to select the Access menu item.
4. Use the Up or Down button to select the required
Access Level.
1
tN4
tN4 Timer 033
033
Made in
Canada
Mmm YYYY
Lo
t #
Mee
ts Class B:
Canadian ICES
FCC P
ar
t 1
5
P
ow
er
:
24
V ±1
0% 50/60 Hz 2.7 V
A
R
ela
y:
24
V (ac) 2 A
10
11-03
R
C
2
3
5
4
Relay
For product instructions see brochure
Use at least 194°F (90°C) conductors
1 2 3
Switch Se
ttings:
R
ela
y NC
4 Schedules
ON
1 Schedule
Re
la
y N
O
1 2 3
Switch Se
ttings:
R
ela
y NC
4 Schedules
ON
1 Schedule
R
ela
y NO
1 Schedule / 4 Schedules (Switch #3)
The 1 Schedule / 4 Schedule switch selects whether the
Timer will host a single schedule, or up to 4 schedules –
(4 Schedules is only available on a tekmarNet
®
4 system).