Gossen STARLITE 2 User Manual
Page 28

28 Gossen Foto- und Lichtmesstechnik GmbH
8.1.1 Measuring correction values
Correction values can also be measured directly.
An evenly illuminated surface and constant light level
are required.
Use the STARLITE 2 in the reflected light mode at
1 ° or 5°.
In the function
, a reference measurement can be
taken by pressing the measuring button
M
.
Designation rF - - in the digital display.
Then, hold the filter in front of the viewfinder and press
the measuring button
AVR
.
The light reducing effect will be indicated automatically in
the display as EV stop and extension factor.
8.1.2 Deleting correction values
In the function
- correction values (chapter 8.1,
page 27) you have two possibilities of deleting pre-
programmed correction values:
- by manually resetting using the setting wheel to
EV 0 and extension factor 1.0 or
- by pressing the measuring button
M
(display rF - -)
- quit the correction value function using the
menu button ( or )
Correction value is deleted.
Symbol
has disappeared from the display.