beautypg.com

Gossen STARLITE 2 User Manual

Page 25

background image

Gossen Foto- und Lichtmesstechnik GmbH

25

6.4

Average value


- Take first measurement using measuring button

M

- Messure up to a further 8 flashes using the
average value measuring button

AVR

.

The individual measurements are shown an the
analogue scale (identical values are only displayed
once, but are taken into account in the calculation of
the average value).
After each measurement with

AVR

, the average

value of all previous measurements is always
displayed. The average value AVR is shown in the
digital display:
at the left with fine adjustment in 1/10 stop
increments and shown as a flashing mark in the
analogue scale, rounded to the nearest 1/2 f-stop.
However, the ambient light portion is not indicated.
In the centre of the display, the number of
measurements M taken is indicated (in the example
4 measurements).