5.5 Averaging value AVR in the t and EV
functions Reflected light measuring
through the viewfinder
-
The first measurement is to be taken with the
measuring button

M

.

- With the average measuring button

AVR

you can

measure up to 8 further contrast spots.
The single measuring values are displayed on the
analogue scale (identical measuring values are only
displayed once, but are taken into consideration when
the averaqe is calculated). After each measurement
with

AVR

, the average of all previous measuring

values is displayed. The average AVR appears on
the left digital display: f or EV with f-numbers in 1/10
increments and flashing on the analogue scale,
rounded to 1/2 stop increments. In the middle of the
display, the number of measurements M is displayed
(4 measurements in the example).


Incident light
with flat or spherical dome
Correspondingly, you can determine the average value
of the illumination of the various lights with the above
mentioned procedure. To do this, you can measure for
example your main, fill-in and background light
individually in the Studio.