Master Programming Mode SXT

When the Master Programming Mode is entered, all available option

setting displays may be viewed and set as needed . Depending on

current option settings, some parameters cannot be viewed or set .

For example, when programming the control valve as a time clock

filter, capacity, water hardness, and other questions will not be asked

by the timer .

A. Setting the Time of Day

1 . Press and hold either the Up or Down buttons until the

programming icon replaces the service icon and the parameter

display reads TD .

2 . Adjust the displayed time with the Up and Down buttons .
3 . When the desired time is set, press the Extra Cycle button to

resume normal operation . The unit will also return to normal

operation after 5 seconds if no buttons are pressed .

Figure 12

B. Entering Master Programming Mode

Set the Time of Day display to 12:01 P . M . Press the Extra Cycle

button (to exit Setting Time of Day mode) . Then press and hold the

Up and Down buttons together until the programming icon replaces

the service icon and the display format screen appears .

C. Exiting Master Programming Mode

Press the Extra Cycle button to accept the displayed settings and

cycle to the next parameter . Press the Extra Cycle button at the last

parameter to save all settings and return to normal operation . The

control will automatically disregard any programming changes and

return to normal operation if it is left in Master Programming mode

for 5 minutes without any keypad input .

D. Resets

• Soft Reset

Press and hold the Extra Cycle and Down buttons for 25

seconds while in normal Service mode . This resets all parameters

to the system default values . Not reset are the volume remaining

in meter immediate or meter delayed systems and days since

regeneration in the time clock system .

• Master Reset

Hold the Extra Cycle button while powering up the unit . This

resets all of the parameters in the unit . Check and verify the

choices selected in Master Programming Mode .

1. Display Format (Display Code DF)

This is the first screen that appears when entering Master

Programming Mode . The Display Format setting specifies the unit of

measure that will be used for volume and how the control will display

the Time of Day . This option setting is identified by "DF" in the upper

left hand corner of the screen . There are two possible settings .

Display Format Setting

Unit of Volume

Time Display

GAL

U.S. Gallons

12-Hour AM/PM

Ltr

Liters

24-Hour

Figure 13

2. Valve Type (Display Code VT)

Press the Extra Cycle button . Use the display to set the Valve Type .

5800 is the only currently available valve type .

3. Regenerant Flow (Display Code RF)

Press the Extra Cycle button . The Regenerant Flow Setting specifies

the type of cycle that the valve follows during regeneration . Note

that some valve types require the valve be built with specific

subcomponents . Ensure the valve is configured properly before

changing the Valve Type setting . This option setting is identified by

"RF" in the upper left hand corner of the screen . There are 8 possible

settings .

Abbreviation

Parameter

dF1b

Standard Downflow Single Backwash

dF2b

Standard Downflow Double Backwash

Fltr

Filter

AIO

Air Injection Oxidizer

dFFF

Downflow Fill First

UFbd

Upflow Brine First

UFFF

Upflow Fill First

Othr

Other

Figure 14

15 W110 LXT Downflow Softeners and SXT Filters