Master Programming Mode LXT

(continued)

C. W110 Filter Meter

Time of

Day

Time of

Backwash

Backwash

Length

Filter

Capacity

Capacity

Remaining

Resin

PM

MODE

Figure 9

1 . Press the Mode button to advance to Time of Backwash . Push

the Up or Down arrow to adjust the time of backwash .

2 . Press the Mode button again to advance to Backwash Length .

Press the Up or Down arrow to adjust your backwash length .

Range is 1-30 minutes .

3 . Press the Mode button again to advance to Filter Capacity . Press

the Up or Down arrow to adjust the setting for filter capacity .

English timer range is 100-90,000 gallons . Metric timer range is

1-900 cubic meters .

4 . Press the Mode button again to advance to Capacity Remaining .

This is not adjustable .

5 . Press the Mode button again to advance to Resin . Use the Up

or Down arrow to adjust the amount of CuFt resin in your tank .

English timer range is 0 .25-3 .0 CuFt . Metric timer range is 5-100

liters .

6 . Hold the Extra Cycle button until the Program icon disappears to

save your programming .

7 . If you are just changing one program step, hold the Extra Cycle

button until the Program icon disappears to save your changes .

If you do not hold the Extra Cycle button until the Program icon

disappears your changes will not be saved .

This unit has a day of the week reserve . It calculates a reserve for

each day of the week based on the past 4 weeks .

D. W110 Filter Time Clock

Time of

Day

Time of

Backwash

Backwash

Length

Days

Between

Regens

Days to

Backwash

Resin

PM

MODE

Figure 10

1 . Press the Mode button to advance to Time of Backwash . Push

the Up or Down arrow to adjust the time of backwash .

2 . Press the Mode button again to advance to Backwash Length .

Press the Up or Down arrow to adjust your backwash length .

Range is 1-30 minutes .

3 . Press the Mode button again to advance to Days Between

Regens . Range is 1 to 30 days .

4 . Press the Mode button again to advance to Days to Backwash .

This is not adjustable .

5 . Press the Mode button again to advance to Resin . Use the Up

or Down arrow to adjust the amount of CuFt resin in your tank .

English timer range is 0 .25-3 .0 CuFt . Metric timer range is 5-100

liters .

6 . Hold the Extra Cycle button until the Program icon disappears to

save your programming .

7 . If you are just changing one program step, hold the Extra Cycle

button until the Program icon disappears to save your changes .

If you do not hold the Extra Cycle button until the Program icon

disappears your changes will not be saved .