beautypg.com

Combination rolling offset – Calculated Industries 4095-B User Guide User Manual

Page 40

background image

40 —

P

IPE

T

RADES

P

RO

Combination Rolling Offset

Unlike a regular rolling offset, the entry and exit fittings for a
combination rolling offset are on different planes and therefore
have different fitting angles from each other.

Horizontal to Vertical

Find the pipe length, and entry and exit fitting angles for a
combination rolling offset with a vertical pipe exit, given a
Roll of 23”, Offset of 15”, and Advance of 29”. Use the box in
Diagram 1 to review the entry and exit pipe perspectives.

0’ -29”

ADVANCE

0’ - 15”
Offset

0’ - 23”
Roll

Unknown
Entry Fitting
Angle

Diagram 1

KEYSTROKE

DISPLAY

ALL

CLEArEd

1. Solve for the pipe length and entry fitting angle
 

OFST 15 INCH

  (Advance)

RUN 29 INCH

   (Roll)

LNTH 39-15/16 INCH



FIT° 43.44°

Do not clear or reset the calculator.

If the box is oriented in a 2-dimensional perspective (Diagram 2),