Chapter 1

Introduction

General

The Model 8578A100GIG is an air cooled, high powered

Termaline Load resistor designed to be efficient, rugged and

trouble free. It is designed to be forced air cooled and is ca-

pable of dissipating RF line power up to 10 kW, with 1000

ft

3

/min (28.32 m

3

/min) or more of externally supplied cool-

ing air through it. Virtually maintenance free and simple to

operate, this unit should provide years of trouble free opera-

tion yet is field repairable in the event of failure of the load

resistor or other components. The RF section is composed of

a parallel combination of resistors.

Description

The unit is rectangular in shape. It is supported on three

sides by four bumper feet on each side. The RF input con-

nector is located on the front panel of the unit. Perforated

side panel grilles on two sides of the unit allow for direct

forced air cooling of the resistors. The transmitter interlock

is located on the front panel of the unit. The rear and side

panels are removable for servicing. Refer to Figure 1, Out-

line Drawing.

WARNING

Do not insert a screwdriver or any thin metal objects

through the perforated cooling air grilles while the

load is in operation. The power within the unit could

arc over and will cause serious injury to personnel and

damage to the unit.