beautypg.com

Programming functions - (cont.) – Bunn DUAL GPR-DBC WITH SMART FUNNEL 41343 User Manual

Page 33

background image

Page 33

PROGRAMMING FUNCTIONS - (cont.)

Procedures to calibrate the bypass flow rate:

1. Place a container, accurately graduated in ounces,

and with a minimum capacity of 60 ounces, below

the funnel on the brewer to be calibrated.

2. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch. Con-

tinue to press and release switch until the display

reads CALIBRATE FLOW?.

3. Press and release YES to advance to the SPRAY

HEAD CAL? function screen. (Pressing NO in the

CALIBRATE FLOW screen will advance to the next

function screen, BREW COUNTERS).

4. Press and release NO to advance to the BYPASS

CALIBRATION screen.

5. Press and release YES. The display should read

CONTAINER READY? If the container is under the

funnel, press YES. The display should read CALI-

BRATE BYPASS .. PRESS BREW TO START.

6. Press and release the BREW switch (on the side

to be calibrated on DUAL brewers). The display

should read CALIBRATE BYPASS .. 60 SEC TO

FINISH. The 60 second timer on the display will

count down to zero. When the counter reaches

zero, the display will change to:

ENTER OZ. (SINGLE brewers)

LEFT or RIGHT OZ. (DUAL brewers), along with

a number.

7. Measure the amount of water in the container, and

using (-) or (+), adjust the amount on the display

to match the amount in the container. Then press

DONE.

8. The display should now read:

NEW BYPS FLOW (SINGLE brewers)

NEW L or R BYPS FLOW (DUAL brewers), along

with the correct flow rate of the bypass in ounces

per minute. After about 5 seconds, the display will

return to the CALIBRATE FLOW screen.

9. Repeat steps 1 - 9 when calibrating the other side

for DUAL brewers.

10. To exit the CALIBRATE FLOW function, press and

release NO to advance to next function screen, or

press and release the ON/OFF switch (either on

DUAL brewers) located on the front switch panel

to exit the CALIBRATE FLOW function and return

to the MAIN SCREEN.

CALIBRATE BYPASS

PRESS BREW START

NEW L BYPS FLOW

XX.X OZM

LEFT OZ XX.X

(-) DONE (+)

NEW BYPS FLOW

XX.X OZM

OZ XX.X

(-) DONE (+)

5 sec

5 sec

CALIBRATE FLOW?

NO YES

SPRAYHEAD CAL?

NO YES

CONTAINER READY?

NO YES

BYPASS CAL?

NO YES

CALIBRATE SPRAY

60 SEC TO FINISH

BREW PRESSED

COUNTS DOWN

TO ZERO

AFTER 1 MINUTE

Left or Right

L or R

SINGLE

BREWERS

DUAL

BREWERS

EXIT TO

NEXT FUNCTION

SCREEN

41343 080108