SPRAY OZ/M (DUAL BREWERS)

This function allows the operator to view or to enter

the actual flow rate coming out of the sprayhead. This

is NOT used to change the actual flow rate, but to tell

the internal controller how fast the water is flowing.

The unit of measure is ounces per minute (Oz/M).

Procedure to adjust the flow rate setting:

1. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Continue to

press and release switch until the display reads,

L SPRY OZ/M. The number represents what the

brewer thinks is the flow rate of the sprayhead in

ounces per minute.

2. If the actual flow rate of the sprayhead is known,

but is different than the number on the display,

use the (-) and (+) to enter the correct flow rate

in ounces per minute.

3. When finished, press and release DONE. This saves

the new setting and advances to R SPRY OZ/M.

When finished setting the right side, press and

release DONE to advance to next function screen,

L BYPS OZ/M. Another alternative is to press and

release either ON/OFF switch located on the front

switch panel to exit R SPRY OZ/M function and

return to the MAIN SCREEN.

SPRAY OZ/M (SINGLE BREWERS)

This function allows the operator to view or to enter

the actual flow rate coming out of the sprayhead. This

is NOT used to change the actual flow rate, but to tell

the internal controller how fast the water is flowing.

The unit of measure is ounces per minute. (Oz/M)

Procedure to adjust the flow rate setting:

1. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

SPRAY OZ/M. The number represents what the

brewer thinks is the flow rate of the sprayhead

valve in ounces per minute.

2. If the actual flow rate of the sprayhead valve is

known, but is different than the number on the

display, use the (-) and (+) to enter the correct

flow rate in ounces per minute.

3. When finished, press and release DONE. This saves

the new setting and advances to the next function

screen, BYPASS OZ/M. Another alternative is to

press the ON/OFF switch located on the switch

panel to exit SPRAY OZ/M function and return to

the MAIN SCREEN.

SPRY OZ/M: XX.X

(-) DONE (+)

BYPS OZ/M: XX.X

(-) DONE (+)

R SPRY OZ/M: XX.X

(-) DONE (+)

L SPRY OZ/M: XX.X

(-) DONE (+)

L BYPS OZ/M: XX.X

(-) DONE (+)

PROGRAMMING FUNCTIONS - (cont.)

41343 080108