PROGRAMMING FUNCTIONS - (cont.)

CALIBRATE FLOW?

NO YES

SPRAYHEAD CAL?

NO YES

CONTAINER READY?

NO YES

CALIBRATE SPRAY

PRESS BREW START

CALIBRATE SPRAY

60 SEC TO FINISH

EXIT TO

NEXT FUNCTION

SCREEN

BREW PRESSED

COUNTS DOWN

TO ZERO

AFTER 1 MINUTE

Left or Right

L or R

LEFT OZ XX.X

(-) DONE (+)

NEW L SPRY FLOW

XX.X OZM

5 sec

OZ XX.X

(-) DONE (+)

NEW SPRY FLOW

XX.X OZM

5 sec

SINGLE

BREWERS

DUAL

BREWERS

CALIBRATE FLOW

This function allows the operator to enter the actual

flow rate of the sprayhead and the bypass (for each side

on DUAL brewers) by dispensing both separately for

one minute. The volumes are then entered in ounces

per minute (OZ/M).

Procedures to calibrate the sprayhead flow rate:

1. Place a container, accurately graduated in ounces,

and with a minimum capacity of 60 ounces, beneath

the funnel (on the side to be calibrated on DUAL

brewers) on the brewer.

2. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Continue

to press and release switch until display reads

CALIBRATE FLOW ?.

3. Press and release YES to advance to the SPRAY

HEAD CAL? function screen. (Pressing NO in the

CALIBRATE FLOW screen will advance to the next

function screen, BREW COUNTERS).

4. Press and release YES. The display should read

CONTAINER READY? If the container is under

the funnel, press YES. The display should read

CALIBRATE SPRAY .. PRESS BREW TO START.

5. Press and release the BREW switch (on the side

to be calibrated for DUAL brewers). The display

should read CALIBRATE SPRAY .. 60 SEC TO FIN-

ISH. The 60 second timer on the display will count

down to zero. When the counter reaches zero, the

display will change to ENTER OZ, along with a

number signifying ounces per minute.

6. Measure the amount of water in the container

and using the (-) or (+), adjust the amount on the

display to match the amount in the container. Then

press DONE.

7. The display should now read:

NEW SPRAY FLOW (SINGLE brewers)

NEW L or R SPRY FLOW (DUAL brewers), along

with the correct flow rate of the sprayhead in ounces

per minute. After about 5 seconds, the display will

return to the CALIBRATE FLOW screen.

8. Repeat steps 1 - 8 when calibrating the other side

on DUAL brewers.

9. To exit the CALIBRATE FLOW program, press NO

to advance to the next function screen, or press

and release the ON/OFF switch (either on DUAL

brewers) located on the front switch panel to exit

the CALIBRATE FLOW function and return to the

MAIN SCREEN.