Procedure to set the sensitivity threshold of the

refill circuit:

NOTE: Make sure the water in the tank is touching

the refill probe.

1. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Press and

release upper right hidden switch until the display

reads REFILL and shows a number on both sides

of the word.

2. To adjust the threshold setting, press (-) to de-

crease, or (+) to increase the setting.

NOTE: Always make sure that the number on the right

is larger than the number on the left when water is in

contact with the refill probe in the tank.

3. When finished, press and release DONE. This saves

the new setting and advances to the next function

screen:

SPRY OZ/M (SINGLE brewers)

PROGRAMMING FUNCTIONS - (cont.)

L SPRY OZ/M (DUAL brewers). Another alternative

is to press and release the ON/OFF switch (either on

DUAL brewers) located on the front switch panel

to exit REFILL and return to the MAIN SCREEN.

SPRAY OZ/M

This function allows the operator to view or to enter

the actual flow rate coming out of the sprayhead. This

is NOT used to change the actual flow rate, but to tell

the internal controller how fast the water is flowing.

The unit of measure is ounces per minute (Oz/M).

Procedure to set ready temperature:

1. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Press and

release upper right hidden switch until the display

reads SET READY.

2. To adjust the ready temperature, press the (-)

button to decrease, or (+) to increase the ready

temperature.

3. When finished, press and release DONE to save

the new setting, exit the SET READY function and

advance to the next function screen, REFILL.

Another alternative is to press and release either

ON/OFF switch located on the front switch panel

to exit the SET READY function and return to the

MAIN SCREEN.

REFILL - Range: 20 to 230

This function allows the operator to adjust the

sensitivity of the refill circuit. This is mainly a trouble-

shooting feature. Water in different geographical loca-

tions can have different conductivities. By adjusting

the sensitivity of the refill circuit, this will allow the

brewer to operate under various water conditions.

XXX REFILL -> XXX

(-) DONE (+)