Procedures to test coil frequency:

1. Place brew funnel(s) into rails of the brewer.

2. Place a GPR beneath brew funnel(s).

3. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Continue

pressing and releasing upper right hidden switch

until SERVICE TOOLS appears.

4. Pressing NO will exit this function and advance to

the next function screen. Press YES to run tests

on various components and outputs within the

brewer.

5. The display should read TEST OUTPUTS.

6. In TEST OUTPUTS screen, press NO. Continue to

press and release NO until the display reads TEST

FREQUENCY.

7. Press and release YES. The display will show the

frequency of the sensor coil circuits. This is for

diagnostic service use when troubleshooting this

circuit.

7. After the coils have been tested, press and release

the ON/OFF switch (either on DUAL brewers)located

on the front switch panel. This will exit the TEST

FREQUENCY function and return to the MAIN

SCREEN.

NOTE: If the operator wishes to test more than one

function in the SERVICE TOOLS section (outputs,

switches, servers, or coil frequency), it is not

necessary to exit the program. Use the flow chart

for SERVICE TOOLS to navigate to a particular

function.

SERVICE TOOLS (cont.)

PROGRAMMING FUNCTIONS - (cont.)

FACTORY DEFAULTS

This function allows the operator to erase all of the

previously entered recipes and ad messages. Factory-

set default values will replace all previous settings.

Procedure to set factory defaults:

1. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Press and

release upper right hidden switch until the display

reads FACTORY DEFAULTS.

2. Pressing NO in this screen will revert to the MAIN

SCREEN. Press YES to replace the defaults. This

advances to WILL REPLACE ALL BREWING SET-

TINGS. This screen will alternate with ARE YOU

SURE?.

3. Press YES to begin the change. While the change

is in process, the display will read RESTORING

DEFAULTS and a count down will begin.

4. When the count down reaches 0 the display will

return to the MAIN SCREEN. The factory default

values will replace all previously entered values.

It will NOT reset the summation Brew Counter.

P3254

EXIT

EXIT

REPLACE

WILL REPLACE ALL

BREW SETTINGS

ARE YOU SURE?

NO YES

FACTORY DEFAULTS

NO YES

41343 080108