Programming functions - (cont.) – Bunn DUAL GPR-DBC WITH SMART FUNNEL 41343 User Manual

Page 31

background image

Page 31

BYPASS OZ/M (SINGLE BREWERS)

This function allows the operator to view or to enter

the actual flow rate coming out of the bypass nozzle.

This is NOT used to change the actual flow rate, but to

tell the internal controller how fast the water is flowing.

The unit of measure is ounces per minute.

Procedure to adjust the flow rate setting:

1. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

BYPAS OZ/M. The number represents what the

brewer thinks is the flow rate of the bypass valve

in ounces per minute.

2. If the actual flow rate of the bypass valve is known,

but is different than the number on the display,

use the (-) and (+) to enter the correct flow rate

in ounces per minute.

3. When finished, press and release DONE. This saves

the new setting and advances to the next function

screen, CALIBRATE FLOW. Another alternative is to

press the ON/OFF switch located on the front switch

panel to exit the BYPASS OZ/M function and return to

the MAIN SCREEN.

BYPASS OZ/M (DUAL BREWERS)

This function allows the operator to view or to enter

the actual flow rate coming out of the bypass nozzle.

This is NOT used to change the actual flow rate, but to

tell the internal controller how fast the water is flowing.

The unit of measure is ounces per minute.

Procedure to adjust the flow rate setting:

1. Press and hold upper right hidden switch until

display reads UNITS. Release switch. Continue

to press and release switch until display reads L

BYPASS OZ/M. The number represents what the

brewer thinks is the flow rate of the bypass valve

in ounces per minute.

2. If the actual flow rate of the bypass valve is known,

but is different than the number on the display,

use the (-) and (+) to enter the correct flow rate

in ounces per minute.

3. When finished, press and release the DONE. This

saves the new setting and advances to R BYPS

OZ/M. When finished setting right side, press and

release DONE to advance to next function screen,

CALIBRATE FLOW. Another alternative is to press

and release either ON/OFF switch located on the

front switch panel to exit the BYPASS OZ/M func-

tion and return to the MAIN SCREEN.

R BYPS OZ/M: XX.X

(-) DONE (+)

L BYPS OZ/M: XX.X

(-) DONE (+)

CALIBRATE FLOW?

NO YES

BYPS OZ/M: XX.X

(-) DONE (+)

CALIBRATE FLOW?

NO YES

PROGRAMMING FUNCTIONS - (cont.)

41343 080108