GPI Connections

GPI Connector Pinout

The GPI inputs and outputs are electrically isolated from the power and ground on
the FS1 frame. There are two inputs and two outputs. Electrical isolation is provided
for up to two pieces of external equipment. The following guidelines apply to the two
GPI inputs and outputs:

Input 1 and Output 1 share a common isolated ground on pins 6 & 8 (I/O

Ground 1).

Input 2 and Output 2 share a common isolated ground on pins 7 & 9 (I/O

Ground 2).

Pin 5, local chassis ground, may only be used as a reference when isolation is not

required.

Both GPI inputs are internally pulled high through a 10K ohm resistor to an

isolated 5V supply, so that a relay contact closure or any device sinking at least
0.4 mA to ground will register a logic low.

Both GPI outputs are 5V TTL compatible, sourcing up to 6mA and sinking up

to 4mA each.

Cabling the System

Where to Place the
FS1

Observe these precautions when placing your FS1:

Plan adequate space for cable routing from the back of the chassis. Ensure that

cable connectors are not stressed and that cables are not bent or crimped.

When rack mounting or stacking multiple FS1 chassis, ensure there is adequate

airspace for cooling around the FS1 units. Note the location of cooling vents on
all equipment next to the FS1 and ensure none are obstructed.

Note:

FS1 units earlier than serial number 2F0482 should not be stacked more than

two together; later units can be stacked vertically without limit as long as there is
adequate cool air supply around the FS1 vents.

Pin Function

1 - GPI Input 1
2 - GPI Input 2
3 - GPI Output 1
4 - GPI Output 2
5 - Chassis Ground

Pin Function

6 - I/O Ground 1
7 - I/O Ground 2
8 - I/O Ground 1
9 - I/O Ground 2

5 4 3 2 1

9 8 7 6