Rockwell Automation TLAR Electric Cylinders Replacement User Manual
Page 12

12 MP-Series and TL-Series Electric Cylinders Replacement Parts
Rockwell Automation Publication MPAR-IN002B-EN-P - September 2012
Replace a Parallel-mount Electric Cylinder Motor or Belt
This procedure is for Bulletin MPAR-
xxxxxx-xxB/D/E electric cylinders. These steps can be
used to change the motor or the actuator cylinder orientation.
Follow these steps to replace the belt, motor, or actuator cylinder.
1.
Disconnect the motor and feedback cables.
2.
If the motor has brake, release the brake on motor so that the rod moves freely.
3.
Position the rod to the center of travel.
4.
Remove the cover from belt housing.
IMPORTANT
Apply Loctite 222 to bolts
M4 and Loctite 242 for bolts M5 during assembly steps.
ATTENTION: Exposed moving parts can cause severe injury. Do not the operate electric cylinder
without the cover in place. Follow the lock-out procedures before servicing the machine.
CAUTION
Hot sur
face.
Do not t
ouch.
Belt Housing