Install the control board kit – Rockwell Automation 2099-K7KCB-1 Kinetix 7000 DC-DC Converter and Control Board Kits User Manual
Page 9

Publication 2099-IN002B-EN-P — October 2008
Kinetix 7000 DC-DC Converter and Control Board Kits
9
Refer to Remove the Drive Covers on page 4 and reverse the order of
steps for your drive module.
8.
Return the drive to operation.
Install the Control Board Kit
Follow these steps to remove and replace the control board.
1.
Label and remove the safe-off (SO), general purpose I/O (GPIO),
general purpose relay (GPR), and ribbon cable connectors from the
control board.
Also, label and remove the fiber-optic (Tx and Rx) connectors, if not
removed earlier.
2.
Remove the six connector stand-offs by using a 3/16 in. thin-walled
socket or nut driver.
3.
Remove the two connector plate screws by using a small Phillips
screwdriver.
IMPORTANT
When replacing the top cover, temporarily remove the
fiber-optic cables from the drive Tx and Rx connectors. This
allows the top cover to seat properly with the chassis.
Kinetix 7000 Drive
(2099-BM07-S is shown)
Ribbon Cable
Connector
Control Board
Screws
Control Board
Connector Plate
Connector Plate
Screws, 2x
Connector Plate
Stand-offs, 2x
Connector Stand-offs, 6x
SO, GPIO, GPR, and
Fiber-optic Connectors
Display Board
IMPORTANT
Thin-walled socket or open-ended wrench is required to
remove the screws due to the clearance between screw
and connector.