Drive Tuning

Chapter 3

3-38

If plotted as velocity versus position, the final deceleration is a straight line
from the Orient Speed/Orient Start point to the Zero Speed/Target Position
point (see Figure 3.1). The orient position loop gain is essentially the slope
of this curve and is defined as:

Orient
Speed

Orient Start

(expressed as degrees/second/degrees or radians/second)

Kp = 6

x

The orient position loop gain that is achieved using the default values for
Orient Speed and Orient Start is:

60 rpm

45.0 degrees

= 8 radians/second

Kp = 6

x

If the velocity or position error were plotted versus time, the deceleration
would be a single exponential deceleration to the target position.

Figure 3.1
Spindle Orient Operation

Orient Start

Slope x 6 = Kp

Final Decel

Begin Final

Deceleration

Target

Position

Orient Speed

Decel from

Running Speed

Spindle Position

Spindle

Speed