34 FLEX Ex 8 Output and HART Analog Modules

Publication

1797-5.3 - September 2011

Repair

Status Indicators

Specifications

ATTENTION

This module is not field repairable. Any attempt to open the module will void the
warranty and IS certification. If repair is necessary, return the module to the
factory.

Interpret the Status Indicators

Status

Description

Flashing red

Channel fault -

Channel 0 indicator will turn red while power-up check is running

Solid green

Power applied to module

Specifications - 1797-OE8
Number of Outputs

8 single-ended, nonisolated

IS input type

Ex ia IIB/IIC T4

AEx ia IIC T4

Class I, II, III Division 1 Group A-G T4

45096

Input Status

Power Status