Mount the Kinetix 350 Drive

Follow these steps to mount the drive.

1. Observe these clearance requirements when mounting the drive to the panel.

IMPORTANT

Mount the module in an upright position as shown. Do not mount the module on
its side.

Drive
Cat. No.

Dimensions A
mm (in.)

2097-V31PR0-LM

185 (7.29)

2097-V31PR2-LM

2097-V32PR0-LM

230 (9.04)

2097-V32PR2-LM

2097-V32PR4-LM

2097-V33PR1-LM

185 (7.29)

(1)

(1)

If you are using an AC line filter, add
50 mm (2 in.).

2097-V33PR3-LM

2097-V33PR5-LM

2097-V33PR6-LM

230 (9.04)

2097-V34PR3-LM

185 (7.29)

(1)

2097-V34PR5-LM

2097-V34PR6-LM

230 (9.04)

A

Additional clearance and different hole patterns are required for side

mount and rear mount AC line filters. See the table and

step 2

for more

details.

Additional clearance is required depending on the other accessory

items installed.

Additional clearance is required for the cable and wires connected to

the top, front, and bottom of the drive.

An additional 150 mm (6.0 in.) is required when the drive is mounted

adjacent to noise sensitive equipment or clean wire ways.

Refer to

page 6

for Kinetix 350 drive dimensions.

25 mm (1.0 in.) Clearance

for Airflow and Installation

25 mm (1.0 in.) Clearance

for Airflow and Installation

3 mm (0.12 in.)

Side Clearance

3 mm (0.12 in.)
Side Clearance