ArmorBlock LP2 8 Sinking Input/ 8 Output Module

5

Publication 1792D-5.42 - July 1999

I/O connectors for this module are shown below.

!

$77(17,21
• Make sure to connect the proper color coded cables

together. DeviceNet cables should connect with
DeviceNet cables and auxiliary outputs should match
auxiliary outputs.

• Make sure all connectors and caps are securely tightened

to properly seal the connections against leaks and
maintain IP67 requirements.

• For maximum noise immunity, input and output cable

return wires must be properly terminated. When inputs
and outputs are connected in loopback, return wires
should be connected together.

• I/O cable length should be less than 30 meters.

I-4

I-5

I-6

I-7

O-4

O-5

I-2

I-3

O-2

O-3

O-6

O-7