Rockwell Automation 1608P ProDySC User Manual, 25 and 50 A User Manual
Rockwell Automation Equipment
Table of contents
Document Outline
- Important User Information
- Additional Resources
- Notes:
- Chapter 1
- Chapter 2
- Installation
- Installation Check List
- Inspecting and Unpacking
- Location (Environment)
- Mounting Considerations
- Mounting the ProDySC
- Bypass Switch
- Bypass Switch Modes
- Bypass Switch Wiring Diagram
- Circuit Breaker Recommendations
- Accessing ProDySC Terminations
- ProDySC Terminations and Ratings
- Notes:
- Installation
- Chapter 3
- Chapter 4
- Chapter 5
- Chapter 6
- Maintenance
- Preventative Maintenance
- Monthly Checks
- 3-6 Month Checks
- POWER_ON
- Informational
- Unit
- T_FAN_ST
- Informational
- Unit
- T_IN_ST_1
- Informational
- Unit
- T_IN_ST_2
- Informational
- Unit
- T_IN_ST_3
- Informational
- Unit
- EXTERNAL
- Auto-Resetting
- Inverter
- RUN_TO
- Auto-Resetting
- Inverter
- LIM_CYCLE
- Auto-Resetting
- Inverter
- STAT_OT
- User Attention
- Static Switch
- OVERLOAD
- User Attention
- Unit
- DC_OV
- User Attention
- Inverter
- CNTRL_UV
- User Attention
- Inverter
- OUTPUT_UV
- User Attention
- Inverter
- INV_OC
- User Attention
- Inverter
- DC_UV
- User Attention
- Inverter
- OUTPUT_OV
- Call Service
- Inverter
- SYNC_ERR
- Call Service
- Inverter
- CONFIG
- Call Service
- Inverter
- CNTRL_MEM
- Auto-Resetting
- Inverter
- UNBALANCE
- Call Service
- Inverter
- AC_V_CHK
- Call Service
- Inverter
- ROLL_CALL
- Call Service
- Unit
- COM_VER
- Call Service
- Unit
- CNFG_TO
- Call Service
- Unit
- CNFG_ERR
- Call Service
- Unit
- FIRM_TO
- Call Service
- Unit
- FIRM_DIFF
- Call Service
- Unit
- SRL_TO
- Call Service
- Unit
- SRL_DIFF
- Informational
- Unit
- T_INV_TO
- Call Service
- Unit
- Fuse Replacement
- Fuse Rating Charts
- Table 13 - DySC Fuse Ratings for 25A Unit
- Fuse Reference
- Fuse Location
- Fuse Rating
- Manufacturer Part Number
- F1, F2, F3
- Main Power Input
- 60A/500V
- Mersen A50QS60-4
- F7
- Input Control Transformer
- 0.5A/600V
- Mersen ATQR1/2
- F4, F5, F6
- Cross-Coupling Transformer
- 15A/600V
- Mersen TRS15R
- F8, F9, F10
- (3 wire models only)
- Neutral Forming Transformer
- 0.75A/600V
- Mersen ATQR3/4
- F17, F18
- Output Control Transformer
- 2A/600V
- Mersen ATQR2
- F1, F2
- (ER models only)
- Extended-Run Module PCB (x3)
- 25A/600V
- Mersen A60Q25-2
- Fuse Reference
- Fuse Location
- Fuse Rating
- Manufacturer Part Number
- F1, F2, F3
- Main Power Input
- 150A/500V
- Mersen A50QS150-4
- F7
- Input Control Transformer
- 0.5A/600V
- Mersen ATQR1/2
- F4, F5, F6
- Cross-Coupling Transformer
- 30A/600V
- Mersen TRS30R
- F8, F9, F10
- (3 wire models only)
- Neutral Forming Transformer
- 0.75A/600V
- Mersen ATQR3/4
- F17, F18
- Output Control Transformer
- 2A/600V
- Mersen ATQR2
- F1, F2
- (ER models only)
- Extended-Run Module PCB (x6)
- 25A/600V
- Mersen A60Q25-2
- Bypass Cat. No.
- Fuse Rating
- Manufacturer Part Number
- 1608P-BP025A480V3
- 35A/600V
- Bussmann LPJ-35SP
- 1608P-BP050A480V3
- 100A/600V
- Bussmann DFJ-100
- Preventative Maintenance
- Maintenance
- Chapter 7