beautypg.com

Rockwell Automation 1492 1771-to-1756 I/O Swing-arm Conversion System User Manual

Page 14

background image

(14)

10000060110 (Version 00)

1771 Digital I/O Module

Cat. Numbers: 1492 Converter for 1771-to-1756 Digital I/O

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

1

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

2

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

3

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

4

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

5

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

6

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

7

1

4

9

2

-C

M

1

7

7

1

-L

D

0

1

1

1

4

9

2

-C

M

1

7

7

1

-L

D

0

1

2

1

4

9

2

-C

M

1

7

7

1

-L

D

0

1

3

1

4

9

2

-C

M

1

7

7

1

-L

D

0

1

4

1771-IAD

X

1756-IA16

1771-IBD

X

1756-IB16

1771-IAD

Y

1756-IH16I

1771-IMD

Y

1756-IM16I

1771-IBN

Z

1756-IB32

1771-IAN

Z

1756-IA32

1771-ID16

Y

1756-IA16I

Y

1756-IH16I

1771-IQ16

Y

1756-IB16I

1771-IVN

Z

1756-IV32

1771-OAD

X

1756-OA16

1771-OBD

X

1756-OB16E

Two 1771-IA/IA2

1756-IA16

1771-OBD

Two 1756-OC8

1771-OBN

Z

1756-OB32

1771-OD16

Y

1756-OA16I

1771-OW16

Y

1756-OW16I

1771-OW

Y

1756-OX8I

1771-OAN

Two 1756-OA16

1771-OA

U

1756-OA8E

Compatible

1756

Digital I/O Module

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

8

F

1

4

9

2

-C

M

1

7

7

1

-L

D

0

0

9

F

1

4

9

2

-C

M

1

7

7

1

-L

D

0

1

0

F

XE

S1

S3

Appendix B

Selection Table for 1771-to-1756 Digital I/O Swing-Arm Converter Modules and Pre-Wired Cables

How To Use Matrix A) In the left most column, find the catalog number of the 1771 digital I/O module

B) Follow that row to the right most column to find the compatible 1756 I/O module. In some cases more than one module exists.
Review the matrix carefully and review the I/O module Installation Manuals with attention to the specifications to determine full
compatibility.

C) Find the column in the row you selected that contains a capital letter (e.g. X) and/or letters/numbers (XE & S1). The catalog
number of the 1492 1771-to-1756 Converter is listed at the top of that column. The capital letters/letter or number/letter from the
row and column intersection indicates the last character(s) of the catalog number for the 1492 cable that connects from the
converter module to the 1756 I/O module (right most column). The FULL cable catalog number is 1492-CONCAB

xx, where xx is

the above letter/number or letter/number combination, except for XE selection (1492-C



XE

Footnotes:

Three digit number to indicates cable length in meters and tenths of meters (005=0.5 meters).

Available lengths = 1.0 (010) and 0.5 (005) meters

Three digit number to indicates cable length in meters and tenths of meters (005=0.5 meters). Available lengths = 1.0 (010) and

0.5 (005) meters

One conversion module required for each 1771-IA/IA2 module. The 1492-C(1)(2)XE cable provides the two 1771 (8-pt) module

into one 1756 (16-pt) module conversion.

The two 1756-OC8 (S1) or 1756-OA16 (S3) must be located directly next to each other in the 1756 chassis.

An F at the end of the conversion module catalog number indicates it is fused to match the functionality of the 1771 module

being replaced.

To understand any issues concerning I/O module compatibility refer to the conversion module wiring diagrams and the specific

I/O module's Installation Manual especially the specification and wiring instruction sections.

Figure 8a

Figure 8b

Figure 9a

Figure 9b

Figure 9c

Figure 6e

Figure 7b

Figure 7c

Figure 8c

Figure 7a

Base-plate slot

Cover-plate
hinge

Figure 9d

Figure 9e