How to program the drive, Chapter – Rockwell Automation 160 160SSC CopyCat Keypad User Manual
Page 13
![background image](/manuals/577724/13/background.png)
Chapter
2
How to Program the Drive
The CopyCat Keypad Program mode and Load mode are used to adjust and save
Program Group parameter values.
Program Group Parameters
In Program mode, the display shows the name, number, and the value of the
currently selected Program Group parameter. For example:
Not all Program Group parameters apply to both the Analog Signal Follower and
Preset Speed model drives. Refer to 160 SSC™ Variable Speed Drive (Series C)
User Manual for more information on Program Group parameters.
Select a Program Group Parameter
There are two methods for selecting a Program Group parameter. You can either
scroll through the parameter list, or enter the parameter number with the numeric
keypad.
Method 1 – Scroll Parameter List
1. Press the Escape key until the Program LED lights.
2. Press the Up or Down arrow key to scroll to the next or previous parameter.
Press and hold the Up or Down arrow key to increase scrolling speed.
The name, number, and value of the newly selected parameter is displayed.
Method 2 – Enter Parameter Number
1. Press the Escape key until the Program LED lights.
2. Enter the two-digit parameter number that you want to display using the
numeric keys.
The display shows the parameter number you entered. For example >58:
To correct an entry, press the Delete key.
Important:
To select and view Program Group parameters, the CopyCat
Keypad must be in Program mode.