4. Disconnect the HIM Communication cable from the connector on the

upper right corner of the Control board and set the cover aside.

Step 3: Remove the Pulse

Transformer and
Switching Power
Supply Boards

Note: The Switching Power Supply circuit board is located on the back of the
Pulse Transformer circuit board. You must remove both boards in order to
replace the Pulse Transformer board.

1. Remove the plug-in terminal from the field input block at the top of the

drive.

2. Remove the four screws that secure the slotted air flow plate to the top of

the drive chassis.

Pull tabs out to
disconnect cable.

IMPORTANT

The air flow plate is also secured to the Pulse Transformer circuit board and
therefore cannot yet be removed. Instructions for doing so are included later in
this procedure.

Air flow plate

Remove screws

Remove plug-in
terminal block

Front of Drive