beautypg.com

Rockwell Automation 20P PowerFlex DC Drive - Frame B AC Current Transducers User Manual

Page 13

background image

PowerFlex® DC Drive - Frame B AC Current Transducers

13

Use the following table to determine the proper tightening torque for the
bus bars connected to the SCR Modules:

Step 6: Install the Pulse
Transformer Board and
Switching Power Supply
Board

Install the Pulse Transformer board and Switching Power Supply board in
reverse order of removal as detailed in Step 3:

Remove the Pulse

Transformer and Switching Power Supply Boards on page 5

.

Verify that the four plastic board stabilizers mounted on the top air flow
plate are placed one on either side of each of the Pulse Transformer and
Switching Power Supply boards.

230V AC Input
Drive Current
Rating Code

DC Amps

AC Line Amps HP

Final Torque

146

146

119

40

4.5

5.5 N•m (40…48.7 lb•in)

180

180

147

50

218

218

178

60

265

265

217

75

11…13 N•m (97.4…115 lb•in)

360

360

294

100

434

434

355

125

460V AC Input
Drive Current
Rating Code

DC Amps

AC Line Amps HP

Final Torque

167

167

136.4

100

4.5

5.5 N•m (40…48.7 lb•in)

207

207

169.1

125

250

250

204.3

150

11…13 N•m (97.4…115 lb•in)

330

330

269.6

200

412

412

336.6

250

ATTENTION: Each gate lead cable must be connected to the
exact connector from which it was removed on the Pulse
Transformer circuit board or damage to the drive may occur.

One plastic stabilizer should be on either side of each board

Air flow plate

Plastic
stabilizers

Top view of Pulse Transformer board

Side cut-away view

Pulse Transformer board

Switching Power Supply board