beautypg.com

Current share boards - optional feature (cont.) – Vicor PFC MegaPAC-HPEL Power Factor Corrected AC-DC Switchers User Manual

Page 27

background image

UG:119

vicorpower.com

Applications Engineering: 800 927.9474

Page 27

Current Share Boards - Optional Feature (Cont.)

Figure 14. Cable Drawing

P1

24.0" +/- 1.0"

Power

T1

-V1

T2

-V2

Red, 22 AWG

Yellow, 22 AWG

Brown, 22 AWG

White, 22 AWG

Black, 22 AWG

1

2

3

4

5

6

1.74"

(44.2mm)

0.12"

(3.0mm)

1.500"

(38.1mm)

0.12"

(3.0mm)

0.900"

(22.9mm)

1.14"

(29.0mm)

0.13" (3.3mm) Dia Non

Plated thru hole 4

places

Molex CT43045F surface mountable

connector. .390" height above board.

J1 Pinout

Figure 13. Mechanical Drawing

Pin Description
1

Power

2

T1

3

-V1

4

T2

5

-V2

6

No Connection

Specifications:
1.
Power: 2-50 Vdc at 5 mA maximum.
2. Accuracy: +/- 1 mV between -Vout connections.
3. Output current when not trimming up: +/- 1 uA (VI-200/J00),

+/-5 uA (Maxi).
4. Use four non-plated through holes with standoffs for mounting.
5. CSB01 MUST be used for current sharing VI-200/VI-J00 converters (VI-200/J00).
6. CSB02 MUST be used for current sharing Maxi converters

(Maxi, Mini and Micros).

PLEASE NOTE, THE CSB IS NOT INTENDED FOR HOT-SWAP APPLICATIONS

Contact your Regional Applications Engineer at 1-800-927-9474

for additional information.