DC OK (Power Good) Connection J2 (and P2 for FinQPAC)

n

DC OK is only available as an option and is not present unless requested.

n

For the QPAC, refer to the J2 connector. J2-3 is Power Good.

n

For the FinQPAC, refer to the P2 connector. P2-3 is Power Good.

n

Use Molex mating receptacle #39-01-0073 with #39-00-0031 terminals provided.

n

Attach terminals to 22-28 AWG stranded wire using Molex tool #57005-5000.

Interface Connections J10

n

Use Molex mating receptacle #39-01-2120 with #39-00-0039 terminals.

n

J10-1 through 8 are Enable/Disable for slots 1 through 8.

n

J10-9 is Vcc, J10-10 is Signal Ground, J10-11 is AC Power OK, and J10-12

is General Shutdown.

n

Attach terminals to 18-24 AWG stranded wire using Molex tool #11-01-0122.

+SENSE

POWER GOOD

SIGNAL GROUND

POWER GOOD INVERTED

Vcc IN

2

1

3

TRIM

4

5

-SENSE

7
6

DC OK/Power Good Connection

on the J2 /P2 Connector

J10-9
J10-10
J10-11
J10-12

Vcc +5V, 0.3A

SIGNAL GROUND

AC POWER OK

GEN SHUTDOWN

J10 INTERFACE

J10-1
J10-2
J10-3
J10-4
J10-5
J10-6

J10-7
J10-8

E/D-1
E/D-2
E/D-3
E/D-4
E/D-5
E/D-6

E/D-7
E/D-8

12

11

10

9

8

7

6

5

4

3

2

1

J10

Interface Connections J10