Specifications 22, Specifications – Vicor PFC MegaPAC-HPEL Power Factor Corrected AC-DC Switchers User Manual
Page 22
UG:119
vicorpower.com
Applications Engineering: 800 927.9474
Page 22
Specifications
Input Characterisitcs
Input Voltage
85-264 Vac, 47-500 Hz 100-380 Vdc
Power Factor
0.99 @ 115 Vac ; 0.95 @ 230 Vac
Inrush Current
25 A pk @ 115 Vac and 230 Vac
Ride Through Time
> 20 ms at nominal line, full load
Power Fail
> 3 ms warning
Conducted EMI
EN55022 Class A; FCC Class A (Certain configurations meet B. Contact factory.)
Surge Immunity
EN 61000-4-5 Installation Class 3, Performance Criteria B
(Temporary loss of output power may occur which is self recoverable)
Dielectric Withstand
Primary to Chassis GND = 2,121 Vdc
Primary to Secondary = 4,242 Vdc
Secondary to Chassis GND = 750 Vdc
Ouput Characterisitcs
Line/Load Regulation
VI-200/VI-J00: ± 0.2% max.10% to full load
± 0.5% max. No load to 10% load
Line Regulation*
Maxi: ± 0.20% max. to 0.3% max LL to HL, Full Load
Load Regulation*
Maxi: ± 0.1% No load to full load
VI-200/VI-J00 Setpoint
Accuracy*
1% for standard voltages; 2% for special or adjustable voltages
Maxi Setpoint Accuracy
1% for standard voltages;
2% for special, adjustable voltages and 48 Vdc outputs
Ripple and Noise
0.15% or 10 mV p-p, whichever is greater, 75% min. load
Output Trim Range
10% -110% of nominal voltage Maxi modules
50% -110% of nominal voltage VI-200/VI-J00 modules
90% -110% of nominal voltage VI-200/VI-J00 modules 10 - 15 V
Overcurrent Trip Point
105 - 125% of full load capability of VI-200/VI-J00 modules
115% typical of full load capability of Maxi modules
Overvoltage Protection
115 - 135% on VI-200 on QPAC and FinQPAC
Efficiency
80% typical
Output Power
PFC MegaPAC-EL
PFC MegaPAC-HPEL
1,600 W at 230 Vac
2,400 W at 230 Vac
1,200 W at 115 Vac
*
1,200 W at 115 Vac
*
*Note: Not to exceed an input current of 15 A.