beautypg.com

Gypsum panel coverage calculator, For s, Brand interior ceiling panels—sag-resistant – USG SHEETROCK Gypsum Panels User Manual

Page 7

background image

Gypsum Panel Coverage Calculator

Size of Panels

No. of Panels

4

Јx8Ј

4

Јx10Ј

4

Јx12Ј

10

320 sq. ft.

400 sq. ft.

480 sq. ft.

11

352

440

528

12

384

480

576

13

416

520

624

14

448

560

672

15

480

600

720

16

512

640

768

17

544

680

816

18

576

720

864

19

608

760

912

20

640

800

960

21

672

840

1008

22

704

880

1056

23

736

920

1104

24

768

960

1152

25

800

1000

1200

26

832

1040

1248

27

864

1080

1296

28

896

1120

1344

29

928

1160

1392

30

960

1200

1440

31

992

1240

1488

Use the following table to determine the maximum frame spacing for
direct application of gypsum panels to wood framing.

Frame Spacing for Single-Layer Application

board application

max. frame

thickness location method

(1)

spacing o.c. in.

3/8

Љ

ceiling

(2)(3)

perpendicular

(3)

16

sidewall

parallel or perpendicular

16

1/2

Љ

ceiling

(4)

parallel

(3)

16

perpendicular

24

(5)

sidewall

parallel or perpendicular

24

5/8

Љ

ceiling

(4)

parallel

(3)

16

perpendicular

24

sidewall

parallel or perpendicular

24

For S

HEETROCK

Brand Interior Ceiling Panels—Sag-Resistant

board application

max. frame

thickness location method

(1)

spacing o.c. in.

1/2

Љ

ceilings

parallel or perpendicular

24

(1) Long edge position relative to framing.
(2) Not recommended below unheated spaces.
(3) Not recommended if water-based texturing material is to be applied.
(4) S

HEETROCK

Brand Gypsum Panels— Water Resistant are not recommended for ceiling where framing is

greater than 12

Љ o.c. for single-layer resilient application where tile is to be supplied.

(5) Max. spacing 16

Љ o.c. if water-based texturing material to be applied.

7