Tips

For 1/4

Љ, 3/8Љ and 1/2Љ thick

panels, use 1-1/4

Љ wallboard

nails. For 5/8

Љ panels, use

1-3/8

Љ wallboard nails.

Drive nails in straight, not at an
angle. Do not overdrive or
countersink nails. This results
in breaking the face paper or
fracturing the gypsum core. If a
nail happens to go in crooked,
hold the panel tight against the
framing and drive a second nail
in about 2

Љ from the nail that

punctured the paper. Then drive
the first nail in below the surface
of the board.

Double-nailing reduces the like-
lihood of nail pops. It is highly
recommended for ceilings. Drive
first nails 12

Љ o.c. along framing

in the field of the board and sec-
ond nails about 2

Љ from the first.

Fasten the perimeter 7

Љ o.c. for

ceilings and 8

Љ o.c. for walls.

6 Screw Attachment

Space screws maximum of 12

Љ

apart on ceilings, 16

Љ on walls

and at least 3/8

Љ from ends and

edges of panels. Sink screws to
just below the panel surface,
leaving the paper intact.

Use an electric screwgun equip-
ped with an adjustable screw
depth control head and Phillips
bit. If an electric drill is used, be
careful not to overdrive screws.