Titus Pneumatic Controls for Dual Duct Terminals IOM User Manual
Page 7
6"
50
0
IN
LET SENS
O
R D
IFFERENT
IA
L
(I
N.
W
.G.
)
0.04
0.03
50
40
70
20
0
10
0
30
0
40
0
CFM
INLET DIAMETER (INCHES)
0.4
0.3
0.2
0.07
0.05
0.1
1.0
0.7
0.5
5"
4"
3000
70
0
1000
2000
7000
4000
5000
10000
9"
8"
7"
10"
12"
16"
14"
6"
500
IN
LE
T S
E
N
S
O
R
D
IFF
ER
EN
TI
AL
(
IN.
W.
G
.)
0.04
0.03
50
40
70
200
100
300
400
CFM
INLET DIAMETER (INCHES)
0.4
0.3
0.2
0.07
0.05
0.1
1.0
0.7
0.5
5"
4"
30
00
700
10
00
20
00
70
00
40
00
50
00
10
000
9"
8"
7"
10"
12"
16"
14"
PNEU-DD-IOM-7.0 8-9-02
AeroCross
TM
Multi-Point Discharge Sensor
Original Titus Multi-Point Discharge Sensor (for use with units shipped before April 1, 2002)
Figure 11. Original Sensor Calibration Curves
Figure 10. AeroCross
TM
Sensor Calibration Curves
Table 5. Original Sensor K-Factors
Table 4. AeroCross
TM
K-Factors
CFM = K
D P
Ö
DP = CFM
K
( )
2
CFM = K
D P
Ö
DP = CFM
K
( )
2
Terminal
Size
04
05
06
07
08
09
10
12
14
16
K-Factor
(CFM)
240
384
538
733
997
1254
1640
2619
3808
4810
Terminal
Size
04
05
06
07
08
09
10
12
14
16
K-Factor
(CFM)
236
406
504
714
935
1281
1675
2428
3647
4607
for Dual Duct Discharge Sensors
for Dual Duct Discharge Sensors
- ACC1 Small System Console (12 pages)
- Alpha BAC-8001/BAC-8201 Cooling Only (21 pages)
- Alpha BAC-8007/BAC-8207 Dual Duct (26 pages)
- Alpha Commissioning Guide (5 pages)
- Analog T3SQ-1 IOM (6 pages)
- Atlas Operating Room Ceiling System (AORCS) (10 pages)
- Displacment Ventilation (22 pages)
- Dual Duct Terminal IOM (2 pages)
- ECM Motor Infrared Controls (2 pages)
- Electric Heat IOM (10 pages)
- Fan Powered Term. IOM (9 pages)
- FFD/FFDR/FFDRA (16 pages)
- FFDE/FFDER/FFDERA (27 pages)
- Fire Rated IOM (4 pages)
- FlowBar IOM (16 pages)
- HAB Horizontal Air Handler Belt Drive (11 pages)
- HEPAlert IOM for RadiaTec Diffusers (7 pages)
- HEPAlert IOM for TLF Diffusers (7 pages)
- Horizontal Basic IOM (6 pages)
- Horizontal High Output IOM (6 pages)
- LSC IOM (27 pages)
- Lynergy (7 pages)
- MAB IOM (9 pages)
- Mixing Box Controls IOM (15 pages)
- ML Border 22 (2 pages)
- ML IOM (8 pages)
- Pneumatic Controls IOM (10 pages)
- QCV IOM (2 pages)
- RAB IOM (12 pages)
- RadiaTec IOM (9 pages)
- Sensor STE-8001 and STE-8201 (34 pages)
- Single Duct Terminal IOM (2 pages)
- SteriTec/LineaTec IOM (2 pages)
- T3SQ-2 Commissioning Guide (4 pages)
- T3SQ-2 IOM (8 pages)
- T3SQ-2 QuickStart Manual (4 pages)
- T3SQ-2 Thermostat Operating Manual (6 pages)
- TAF-L Perimeter System IOM (10 pages)
- TAO IOM (3 pages)
- TBD/TBDR-FR IOM (2 pages)
- Thermal T3SQ-4, IOM (2 pages)
- TMR / TMRA IOM (4 pages)
- UnderFloor Products IOM (20 pages)
- Universal Control Card (7 pages)