Hampton® H15-1 Direct Vent Freestanding Gas Stove
5
SAFETY LABEL
This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.
NOTE: Hampton
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back
up in the same room where the gas appliance is installed.
C 2" / 50mm
E 2" / 50mm
A 6" / 150mm
B 0" / 0mm
Minimum ceiling height from top of unit:
mm
Minimum plafond hauteur en haut de
l'appareil: 24"/610mm
24"/610
Minimum clearance of Vent Terminal
to Outside Corner & Inside Corner:
with AstroCap 6"/150mm
with Dura-Vent Cap 12"/300mm
E
E
A
A
A
B
36” max
36” max
Left Side Wall
Right Side Wall
Horizontal
Pipe
5"
WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
Pression d’allimentation minimum
Pression
la tubulure d' chappement lev e
Pression
la tubulure d' chappement basse
а
й
й
й
а
й
18,000 Btu/h (5.28 Kw/h)
10,500 Btu/h (3.08 Kw/h)
#47 DMS
0-4500 ft/pi (0-1372m)
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
й
й
12"
WC/C.E. (3.00 kPa)
11" WC/C.E.
(2.74 kPa)
2.9" WC/C.E.
(0.72 kPa)
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
Maximum Input
Minimum Input
Orifice size
Altitude
Pression d'allimentation minimum
Pression
la tubulure d' chappement lev e
Pression
la tubulure d' chappement basse
а
й
й
й
а
й
18,000 Btu/h
(5.28 Kw/h)
10,600 Btu/h
(3.10 Kw/h)
#55 DMS
0-2000 ft/pi
(0-610m)
15,500 Btu/h
(4.54 Kw/h)
8,200 Btu/h
(2.40 Kw/h)
#56 DMS
2000-4500 ft/pi (610-1372m)
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
й
й
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
й
й
A
Left Side Wall
Right Side Wall
C
Vertical
Pipe
See Manual for details
Model/Modele:
H15-LP1
Listed:
Certified for/Certifi e pour:
Tested to:
WN# 16443
CANADA and U.S.A.
CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
é
PROPANE GAS STOVE:
Model H15-LP1
L
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Modéle H15-LP1
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
301
DUPLICATE SERIAL NO.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/
Fabrique au Canada
Minimum Clearances to Combustibles /
Degagement Minimum
De Materiaux Combustibles
Serial No./ No de serie
918-494b
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation
Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not
prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1
en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured
Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
For use with glass doors certified with the appliance only.
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U.
seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec
d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
301
Model/Modele:
H15-NG1
NATURAL GAS STOVE:
Model H15-NG1
L
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE:
Modéle H15-NG1
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -