beautypg.com

Installation, Dv stove horizontal vent kit – Regency Hampton H15 Small Gas Stove User Manual

Page 21

background image

Hampton® H15-1 Direct Vent Freestanding Gas Stove

21

INSTALLATION

DV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION

Review the following sequence of instructions
which are typical of most installations. The
sequence may vary depending on wall thick-
ness. Refer to the "Exterior Vent Terminal
Locations" and "Rigid Pipe Venting Systems"
sections for vent location and clearance
dimensions, and the "Vent Restrictor Posi-
tion" for the correct positioning.

1) Set the unit in its desired location. Check

to determine if wall studs will be in the way
of the venting system, adjust location until
all clearances are met and there are no
obstructions.

Note: A 1-1/2"(38mm) clearance around the

outer pipe must be maintained except
that only a 1" (25mm) clearance is
needed at the termination end.

IMPORTANT:
Do not locate termination hood
where excessive snow or ice
buildup may occur. Be sure to check
vent termination area after snow
falls, and clear to prevent accidental
blockage of venting system. When
using snow blowers, make sure
snow is not directed towards vent
termination area.

b) Install wall thimbles on both interior

and exterior wall with 4 wood screws
(#8 x 1") per thimble.

c) Attach the 2 piece adjustable pipe sec-

tion to the vent terminal and slide into
position from the exterior. The larger
diameter end of the adjustable pipe
goes to the vent terminal.

d) Install the 90

o

elbow onto the adjust-

able pipe to determine the vertical
centerline.

Note: if the centerline cannot be met,
the adjustable sections will have to
be cut.

e) Cut the 4 ft. section of rigid pipe to

length. Attach the 45

o

elbow to the rigid

pipe, and ensure that the pipe length
when cut (with the 45

o

elbow) will seat

onto both the starter collar and the 90

o

elbow. Crimped section of rigid pipe
seats into the 90

o

elbow. Only cut

the uncrimped side of pipe.

Dismantle all pipe sections including vent
terminal.

2) Assemble

a

trial fi t to determine the vertical

center-line for the vent termination.

a) Cut a 9-1/2" x 9-1/2" (241mm x 241

mm) square hole on both the interior
and exterior wall.

DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed
to install the H15-1 Direct Vent unit with up & out horizontal and vertical vent dimensions. For installations that
require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termina-
tion Kit" and "Dura-Vent Venting Components" sections.

Qty.

Description

1) 1

Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm)

inside

diameter

2) 1

Flex Liner, compressed aluminium 2 ply liner, 4" (102mm)

inside

diameter

3) 4 spring

spacers

4) 1

90 deg. Elbow

5) 1

Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.

6) 1 Thimble

Cover

7) 1

Wall Thimble (2 pcs.)

8) 1 Adapter
9) 1 AstroCap Termination Cap
10) 2

Trim Collars

11) 1

tube of Mill-Pac, high temperature sealant

12) 12 Screws, #8 x 1/2" Self tapping, Stainless Steel
13) 14 Screws, #8 x 1/2" Self tapping, Black
14) 4

Screws #8 x 1-1/2" Drill Point, Black

15) 4

Screws #8 x 1-1/2" Drill Point, Stainless Steel

16) 8

Wood screws #8 x 1"

Note:

a) Liner sections should be con-

tinuous without any joints or

seams.

b) This is an approved system,

therefore components in this

system must not be substituted

for any other manufacturer's

products.