Figure 19. Bulb Replacement - 1
ROTATE
COUNTER-CLOCKWISE
Figure 20. Bulb Replacement - 2
Figure 21. Bulb Replacement - 3
7.4 Fuse Replacement
1. Refer to figures 22 & 23. Remove the plug from outlet.
2. Locate two fuse blocks.
Ceiling and Wall Models: Unscrew the plastic screws from transformer cover. Take off
the transformer cover. Locate fuse holders (2) inside the transformer housing.
Mobile Models: Locate two fuse blocks on the bottom of the transformer housing.
3. Push in and turn the fuse holder counter clockwise. Remove the fuse holder from the fuse
block.
4. Remove and replace the fuse. A blown fuse may not be noticeably different from a good
one. BOTH FUSES SHOULD BE REPLACED AT THE SAME TIME.
5. Follow procedure in reverse to return lamp to operating condition.
6. Fuse Replacement Specifications:
a. USA : Sunnex part# 18565 (2 AMP, 250V, 1/4” X 1-1/4”)