22

Figure 19. Bulb Replacement - 1


ROTATE

COUNTER-CLOCKWISE

Figure 20. Bulb Replacement - 2




Figure 21. Bulb Replacement - 3

7.4 Fuse Replacement

1. Refer to figures 22 & 23. Remove the plug from outlet.
2. Locate two fuse blocks.

Ceiling and Wall Models: Unscrew the plastic screws from transformer cover. Take off
the transformer cover. Locate fuse holders (2) inside the transformer housing.

Mobile Models: Locate two fuse blocks on the bottom of the transformer housing.

3. Push in and turn the fuse holder counter clockwise. Remove the fuse holder from the fuse

block.

4. Remove and replace the fuse. A blown fuse may not be noticeably different from a good

one. BOTH FUSES SHOULD BE REPLACED AT THE SAME TIME.

5. Follow procedure in reverse to return lamp to operating condition.
6. Fuse Replacement Specifications:

a. USA : Sunnex part# 18565 (2 AMP, 250V, 1/4” X 1-1/4”)

This manual is related to the following products: