MODEL NUMBER NOMENCLATURE — 548F UNITS
(ODS Model Number)
ARI* CAPACITY RATINGS
548F036-060
548F072-120
LEGEND
*Air Conditioning and Refrigeration Institute.
†Applies only to units with capacity of 60,000 Btuh or less.
**The IPLV applies only to 2-stage heat pump units.
††Not ASHRAE 90.1-99 compliant.
NOTES:
1. Rated in accordance with ARI Standards 210/240-95 and 270-95.
2. Ratings are net values, reflecting the effects of circulating fan heat.
3. Ratings are based on:
Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature and 95 F db
air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F db out-
door entering-air temperature.
High-Temp Heating Standard: 70 F db indoor entering-air temperature and 47 F
db, 43 F wb outdoor entering-air temperature.
Low-Temp Heating Standard: 70 F db indoor entering-air temperature and 17 F
db, 15 F wb outdoor entering-air temperature.
UNIT
548F
NOMINAL
TONS
COOLING
HEATING
(High Temp)
SOUND
RATING
(decibels)
Capacity
(Btuh)
SEER†
Capacity
(Btuh)
HSPF
Belt
Drive
Direct
Drive
036
3
35,600
10.20
10.00
34,400
6.7
84
048
4
46,500
10.00
9.70
46,500
7.0
80
060
5
57,000
10.00
9.90
57,000
7.5
82
UNIT
548F
NOMINAL
TONS
COOLING
HEATING
(High)
HEATING
(Low)
IPLV**
SOUND
RATING
(decibels)
Capacity
(Btuh)
EER
Capacity
(Btuh)
COP
Capacity
(Btuh)
COP
072††
6
70,000
9.05
72,400
3.20
42,000
2.14
—
82
090††
7
1
/
2
86,000
9.00
78,000
3.00
39,000
1.80
9.3
86
102††
8
1
/
2
96,000
8.90
96,000
3.00
55,000
2.00
8.85
86
120††
10
112,000
9.00
105,000
3.10
59,000
2.00
9.0
84
COP
—
Coefficient of Performance
db
—
dry bulb
EER
—
Energy Efficiency Ratio
HSPF
—
Heating Seasonal Performance Factor
IPLV
—
Integrated Part-Load Values
SEER
—
Seasonal Energy Efficiency Ratio
wb
—
wet bulb
Voltage Designation
E – 460-3-60
J – 208/230-1-60†
P – 208/230-3-60
T – 575-3-60
548F E X 090 000 AA
548F – Single-Package
Heat Pump
Unit
X – No Heat Installed.
(Field-installed electric heaters available.)
Factory-Installed Options*
Nominal Tons
036 – 3
090 – 7-1/2
048 – 4
102 – 8-1/2
060 – 5
120 – 10
072 – 6
Electric Heaters
000 – No factory-installed electric heaters
LEGEND
*Refer to Trade Price Sheets or contact your local representative for specific
information regarding which options are available on which units.
†Single-phase is only available on 036-060 size units.
NOTE: The example model number 548FEX090000AA designates a 7
1
/
2
ton
460-3-60 volt electric heat pump unit with factory-installed economizer.
ODS
—
Order Distribution System
50
T
F
Q
0
04
-0
12
5
48F
036
-1
20