Standard Parameters Screen

 Click Next. The Advanced Parameters tab is opened.

 Specify the following Advanced Parameters if needed. This is only necessary in

non-standard environments:

o

Use shadow removal – Visible shadows may deteriorate counting results. This

parameter reduces the shadow effect. It is enabled by default.

o

Sensibility – Value between 0 and 1, default value 0,5. This parameter can be

increased for low contrast images or decreased for high contrast images.

o

Min Shadow threshold – Don’t change this parameter unless requested by your

installer or support.

o

Max Shadow threshold – Don’t change this parameter unless requested by your

installer or support.

o

People lifespan – This parameter is used to configure how fast people are entering

after each other. By default this is 0.5 seconds. In crowded environments this can be
lowered (minimum = 0.3 seconds).

Version 2.1.0.0 Series

2010 Quadrox NV