beautypg.com

Opi-2101, Quick start guide – Opticon OPI 2101 User Manual

Page 4

background image

How to connect

Connect the 9-pin D-Sub female connector to the

serial port of the host computer.

Insert the AC/DC adaptor plug into the DC jack of the

interface cable. Start up the host computer.

Quick Start Guide

• Read this quick start guide carefully before installing and/or using this product.

• Keep this quick start guide for future reference and store it in a safe place.

Introduction

OPI-2101

Copyright

©

2008, Opticon All rights reserved.

Notice

• This quick start guide may be revised or withdrawn at any time without prior notice.

• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted

to any electronic or machine readable form without prior written consent of Opticon.

• Trademarks used are property of their respective owners.

• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect

damages howsoever caused.

Caution and Warning

 

1. Laser Safety

Do not stare into the laser beam.
2. Handling Instructions

OPI-2101

• Do not attempt to disassemble, modify or update this device.

• Operating the scanner while operating machinery or a vehicle can be distracting.

• Do not plug/unplug the connector before disconnecting the power.

• Do not drop or put heavy items on this product/cable.

• Do not pinch or forcibly bend the cable, especially at very low temperature.

• Do not swing the device around by the cable.

• Do not insert foreign substances into the device.

• Do not use/leave this device in the following areas.

- In areas exposed to direct sunlight for long periods of time

- In dusty environments

- In risk for an exposure to chemicals

- Near water or other liquids, as well as in extremely high humidity

- Near heat sources, such as radiators, heat registers, stoves, or other types of devices that produce heat

- Near TVs, microwaves, medical devices, or low-power radio stations

- In the reach of blinking lights such as CRT

- In the reach of small children

• Do not throw the device into the fire.

• The instantaneous voltage drop by thunderbolt or other reasons may cause malfunctions.

• When cleaning this product, rub gently with either a soft dry cloth or a damp cloth with mild detergent.

AC/DC Adapter

• Do not use this product with a device which does not meet the specifications.

• Do not use any plug connectors other than the ones provided in this product package.

• Insert the plug connector properly into a socket.

• This product may produce heat when using but it does not affect its performance.

• Do not damage the cable.

• Do not bend or pull the cable forcibly.

• Do not place heavy objects on the cable.

• Do not hold the adapter on the cable when unpluging this product.

• Do not plug in or out this product with wet hands.

• Do not store or use this product in direct sunlight, near heating equipments or in dusty area.

• Do not cover this product with cloth.

• Please stop using this product if it starts producing heat or smoke.

• Unplug this product when it is not in use.

• Unplug this product when cleaning.

(Please refer to the specification manual and instruction guide for details.)

OPI21019062-0-00

The Netherlands Opticon Sensors Europe B.V.

tel: +31 (0)23-5692700

/ email: [email protected]

U.S.A.

Opticon Inc.

tel: 800-636-0090

/ email: [email protected]

France

Opticon S.A.S.

tel: +33 (0)1-41461260

/ email: [email protected]

Germany

Opticon Sensoren GmbH

tel: +49 (0)6074-91890-0

/ email: [email protected]

Italy

Opticon s.r.l.

tel: +39 (0)051-6321800

/ email: [email protected]

Spain

Opticon Sensores S.L.

tel: +34 (0)902-747469

/ email: [email protected]

Contact

Sweden

Opticon Sensors Nordic AB

tel: +46 (0)8-58548560

/ email: [email protected]

United Kingdom Opticon Limited

tel: +44 (0)1582-635100

/ email: [email protected]

Taiwan

Opticon Far Eastern Ltd.

tel: +886 2-27597444 / email: [email protected]

China

Opticon Sensors Europe B.V., Shanghai Representative Office

tel: +86 21-64480881

/ email: [email protected]

Australia

Opticon Sensors Pty. Ltd.

tel: +61 (0)2-43402666

/ email: [email protected]

Brazil

Opticon Sensors Europe B.V., Latin American Office

tel: +55 11-5081 2088

/ email: [email protected]

Please contact OPTICON or your local dealer.

More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.

Before Getting Started

No.

Item

Product No.

Function

1

Scanner

OPI-2101

Imager Scanner

2

AC/DC Adapter

(*1)

SFP0602000P-PSE

AC/DC Adapter with Plug Connector

3

Plug Connectors

(*2)

−−−−−−−−−−−

For Europe, for the UK, for Australia and for the US and Japan.

4

Wedge branch cable

(*3)

−−−−−−−−−−−

Connects the keyboard and Wedge straight cable to the host computer.

5

Quick Start Guide

OPI21019062-0-00

Provides product information and instruction guide.

What's in the Box

(*1)(*2)

Not enclosed in a package of the OPI-2101-USB.

(*3)

Enclosed only for the package of the OPI-2101-Wedge.

Detailed View

Overview

OPI-2101 Basic Specifications

Parameter

Specifications

Physical

Features

Size

(H)175 x (W) 72 x (D) 95 mm

Weight

Approx. 165g (excluding the cable)

Operation

Section

Scan Confirmation Buzzer and LED
Keys

1 key (Trigger key)

Interfaces RS-232C

9600bps

to 115.2kbps

USB

Full-Speed 12Mbps ( HID/VCP ) Hi-Power Bus-powered

Wedge

DOS-V Keyboard(Selectable of the

connection/disconnection of keyboard)

Control

Section

ASIC

OEY-0402 CPU:ARM-1026EJ-S Core:160MHz

SDRAM

128 Mbits (1M x 4Banks x 32Bits)

Flash ROM

16 Mbits (1M x 16Bits) Flash Memory

Scanning

Section

Light Source

Wavelength

8 (for USB) to 10 InGaN White LEDs

Peak Wavelength: 468nm/568nm

Scanning Method SXGA CMOS area sensor (1280 x 1024 pixels)
Laser aiming spot

Wavelength/Output

1 Red Laser

650±10nm/1mW or less

Supported

Symbologies

(1D)

JAN-8/13, EAN-8/13, UPC-A/E, NW-

7(Codabar), Code 39, Code 93, Code 128

(EAN-128), IATA, MSI/Plessey, Industrial 2

of 5, Interleaved 2 of 5, RSS, S-Code, Korean

Postal Authority Code, UK-Plessey, Matrix 2

of 5, Telepen, Tri-Optic, CodablockF

(*)

Supported

Symbologies

(2D)

PDF417, MicroPDF417, QR Code, Micro QR Code,

Data Matrix (ECC 0-140,200), Maxi Code (modes 2

to 5), Aztec Code, EAN.UCC Composite bar code

Power

Supply

Section

Operating voltage 4.5 to 6.6V
Current

consumption

(at 6.0V)

Peak (when scanning or decoding): 600mA

Average (when scanning or decoding): 340mA

Stand-by: 120mA

Durability Operating Temp. -20 to 50 deg. C

Storage Temp. -25 to 70 deg. C
Operating Humidity 5 to 95 % (non-condensing)
Storage Humidity 5 to 95 % (non-condensing)
Ambient Light

Immunity

Fluorescent: up to 10,000lx
Sunlight: up to 100,000lx

Dust-and Drip Proof IP42
Static Electricity 15kV (no destruction)

Shock

Endurance

Dropped once from each of 5 angles onto

concrete floor from a height of 200cm with

no defects found. (Total 5 times)

No.

Part

Function

Status LED

Turns blue when the OPI-2101

registers a successful read and red

when it fails.

Buzzer Hole

Buzzer sounds through the buzzer

hole.

Aiming Laser

Illuminates laser beam aiming at

symbologies.

Receiving Lens

Receives images through the lens.

Floodlighting

Illuminates barcodes in the dark.

Trigger Switch

Starts scanning/decoding barcodes.

Confirm that you have the following items before getting started. Please be noted that the contents may differ

depending on interface specifications. Please contact the nearest dealer if items are damaged or missing.

Laser Beam Aiming Guide Setting

(Disabled by default)

In order to assist for clear recognition of the scanning area, the floodlight of this product using white LEDs is guided by a

red laser aiming spot.

Enable Laser beam aiming guide

serial command : D3D

Disable Laser beam aiming guide

serial command : D3E

• Do not use the keyboard during data transmission to the

host computer or data transmission may fail.

• Do not turn the adapter ON or OFF while using the

keyboard. Doing so may cause a malfunction.

• Japanese Kanji data or images cannot be transmitted via

this Wedge interface.

• Do not carry out any scanning or keyboard operation

before the host computer s operating system is fully

activated.

Memo

                      

Interface

The OPI-2101 supports RS-232C, USB, and Wedge interfaces.

With Wedge Interface, it is selectable to connect or disconnect the keyboard.

Wedge Interface

How to connect

Connect the Wedge Interface cable to the branch

cable. Connect the 6-pin mini-DIN female connector

(marked as "DOS/V SCAN") to the 6-pin mini-DIN male

connector of the interface cable.

Connect the 6-pin mini-DIN male connector (marked

as "DOS/V HOST") to the keyboard connector of the

host computer and connect the 6-pin mini-DIN female

connector (marked as "DOS/V KEY") to the keyboard.

Insert the AC/DC adaptor plug into the DC jack of

the interface cable. Start up the host computer.

RS-232C Interface

• This interface does not require an AC/DC adaptor.
• Japanese Kanji data or images can be transmitted via USB-VCP

interface not via USB-HID interface.

• This interface need to be connected to a high-powered bus

(500 mA max.) USB terminal.

• When using the USB-HID interface do not carry out scanning

or keyboard operation before the host computer's operating

system is fully activated.

Universal AC/DC Adapter

Basic Specifications for Universal AC/DC Adapter

For

Europe

For

the UK

For

Australia

For the

US and Japan

Plug Connectors

Parameter

Specifications

Physical

Features

Size

(H)75 x (W)47.5 x (D)28mm (excluding boss)

Cable Length 1.8m
Colour

Black

Input

Power Voltage AC 90V to 265V
Supply Current 500mA Max

Output

Power Voltage 5.7V to 6.3V
Maximum Current 2A Max

Environmental

Specification

Operating Temp. 0 to 40 deg. C
Operating Humidity 25 to 85% (non-condensing)
Storage Temp. -20 to 60 deg. C
Storage Humidity 20 to 90% (non-condensing)

Universal AC/DC Adapter

φ4.0±0.05

φ1.7±0.05

In auto trigger mode, the scanner captures a barcode image using the ambient light. The scanner detects the dark pixels

and light pixels in the detection area. The scanning operation stops within the designated duration.

Auto Trigger Setting

(Disabled by default)

Enable Auto Trigger

serial command : +I

Disable Auto Trigger

serial command : +F

• Japanese Kanji data or images can be transmitted via RS-

232C interface.

Memo

DOS/V

HOST

DOS/V

SCAN

DOS/V

KEY

OPI-2101

Connect to

the Host

Connect to AC/DC Adapter

Connect to Wedge branch cable

Wedge branch cable

Mini-Din 6 Pin (Male)

Mini-Din 6 Pin (Female)

Connect to

the Keyboard

Mini-Din 6 Pin (Female)

Mini-Din 6 Pin (Male)

OPI-2101

D-Sub9 Pin (Female)

Connect to

the Host

Connect to AC/DC Adapter

Without keyboard

serial command : KL

With keyboard

serial command : KM

(*)

In case of enabling Codablock F, be sure to disable Code128. Damaged

Codablock F may be taken for Code 128. Read about configuration options

(by Opticonfigure) on www.opticon.com

USB Interface

USB-HID (Human Interface Device) and USB-VCP

(Virtual Communication Port) are available.

How to Install a USB Driver for USB-VCP

To connect the OPI-2101 to a host using a dedicated USB

cable, you must first install a dedicated USB driver on the host.

If the driver CD is not included in the box, visit the Opticon

website (www.opticon.com) section Service & Support |

Download Software to download the available driver.

Operating Environments

OS :

Windows 2000 / XP / VISTA

Hard Disk Space :

10MB or more

Memory :

64MB or more is recommended

Communication Port :

USB1.1 or higher

USB Driver for USB-HID

The driver for USB-HID is inserted in the operating system and

does not require further installation.