beautypg.com

Opticon ECB 1000 User Manual

Page 8

background image

8

-

Opticon Ethernet Converter

2.2.2

Method 2: Using AT-commands via RS232

It is also possible to configure the Ethernet box by sending modem (AT-)commands via RS232. You can send
these commands manually via an RS232 monitor (i.e. Hyperterminal or Appload) or for a quicker setup you can
also connect an (RS232) barcode reader and scan configuration barcodes.

The following AT-commands can be send to configure the Ethernet box.

Option

Command

Example + barcode

Default host name

AT+NAME

Default IP-address

AT+IP

Default Gateway IP

AT+GATE

Default DNS server IP

AT+DNS

Default subnet IP mask

AT+MASK

Disable/enable DHCP

AT+DHCP

Baudrate

AT+BAUD

Important notes:

§ All commands must be terminated with a carriage return

§ Make sure you send the commands at the correct baud rate (default is 115200bps)

§ The review the current settings use the following command: 'AT?'.

§ If a command is accepted the Ethernet box will respond with OK