beautypg.com

Omnitron Systems Technology FlexSwitch 600XC 2Fx/4Fx User Manual

Omnitron Systems Technology Communication

background image

User W

arranty Registration

Please register on-line

@ http://www

.omnitron-systems.com

or complete both sides

and mail or fax this registration form to:

Omnitron Systems T

echnology

, Inc.

27 Mauchly #201

Irvine, CA 92618, USA

Fax: (949) 250-6514

Name:

_________________________________________________

Company:

______________________________________________

Address:

______________________________________________

______________________________________________

City: ___________________ State: _______ Zip Code:

________

Country:

_______________________________________________

Phone: ____________________ Fax:

_______________________

E-mail:

_________________________________________________

Please complete both sides of this form

FlexSwitch

TM

600XC 2Fx and 4Fx

User Instructions

Description:

The FlexSwitch

TM

600XC described here is a two or four-

port 100Base fiber switch. It supports multimode and
single-mode fiber and operates in half duplex (HD) or
full duplex (FD). The following models are described
here:

Ext. Power

Int. Power

Model

Model

Fiber

6720-F1-F2

1

6520-F1-F2

1

2@100 SC

6721-F1-F2

1

6521-F1-F2

1

2@100 ST

6730-F1

2

6530-F1

2

4@100 SC

6731-F1

2

6531-F1

2

4@100 ST

1.

On models 6720, 6721, 6520 and 6521, the “

F1” denotes the fiber

type on port 1 and the “

F2” denotes the fiber type on port 2.

2.

On models 6730, 6731, 6530 and 6531, the “

F1” denotes the

fiber type on all four ports.

Power Adapter Notice:

1. When used with an external power adapter (models

67xx), this product must only be used with Omnitron
Supplied Power Unit model number 9112-PS.

2. When used with an external power adapter (models

67xx), this product is intended to be and must be used
only with a Listed Direct Plug-In Power Unit marked
“Class 2” and rated at 9Vdc, 1.2 Amp.

3. Models using internal power supplies (models “65xx”)

are capable of auto switching from 100-230V, and
are supplied with a U.S. type NEMA 5-15 power cable.

4. For products being shipped outside of the U.S., the

user is required to install a properly grounded IEC
320-appliance cable with a minimum rating of 10
AMPs.

5. User-supplied cables must meet the required safety

agency approvals, applicable international standards
and electrical ratings for the region.

WARNING!

Before inserting the Power Adapter, verify that

the power on the unit is appropriate

for your AC line voltage source.

Mounting and Cable Attachment:

The FlexSwitch 600XC can be used as a tabletop unit
or wall-mounted using a wall-mounting kit.
After connecting to an appropriate power outlet, attach
the FlexSwitch 600XC via appropriate fiber cables (SC
or ST as needed) to each 100Base-Fx Fast Ethernet
fiber switch, hub or workstation. The fiber’s transmit (Tx)
must attach to the receive side on any opposing devices

and the receive (Rx) must attach to the transmit side.
Set the “Half/Full Duplex” switches as needed.

Switch Settings:

“Full-Duplex (FDX) / Half-Duplex (HDX)” Switch:
When the FDX / HDX switches are set to “Half Duplex,”
the corresponding fiber ports operate in half duplex.
When set to “Full Duplex” (factory setting), the
corresponding fiber ports operate in full duplex.
Half duplex must be used when connecting to a hub.
Full duplex should be used when connecting to a switch
or a full-duplex workstation or server.

LED Indicators:

Function Color

Description

Link/Act

Green

Off - No Link detected
On - Link detected
Flashing - Data Received

FDX/HDX Green

Off: Set to Half-Duplex
On: Set to Full-Duplex

Technical Support

For help with this product, contact our Tech Support:
Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address:

Omnitron Systems Technology, Inc.
27 Mauchly #201
Irvine, CA 92618 USA

Email:

[email protected]

URL:

http://www.omnitron-systems.com

Please use the following to identify your model:
F1 = 0, 2, 3

F2 = 0, 2, 3

0 = Multimode Lx

1300nm

2 = Single-mode Lx

1300nm

3 = Single-mode Lx/LH 1300nm Extended Distance

User W

arranty Registration

Please register online at

http://www

.omnitron-systems.com

or complete both sides

and return this form to Omnitron Systems.

FlexSwitch T

ype: ________ Fiber T

ype:_______Connector: _______

Model:

_________________________________________________

Serial Number: ______________ Purchase Date:

______________

Purchased From: _________________________________________

Address:

______________________________________________

City: ___________________ State: _______ Zip Code:

________

Country:

_______________________________________________

Comments and Suggestions:

_______________________________

______________________________________________________

______________________________________________________

Please complete both sides of this form

Notes:

____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
________________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________

Warning

The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other
than that contained in the operating instructions, unless
you are qualified and certified to do so by Omnitron
Systems Technology, Inc.

Caution

All user-required operations can be performed without
opening the unit. Never attempt to open or remove the
cover or tamper with the unit.

Warranty

This product is warranted to the original purchaser
against defects in material and workmanship for a period
of TWO YEARS from the date of shipment. A LIFETIME
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90
days from the date of shipment. TO REGISTER,
COMPLETE AND MAIL OR FAX THE REGISTRATION
PORTION OF THIS INSTRUCTION MANUAL TO THE
INDICATED ADDRESS. Or you may register your
product on the internet at http://www.omnitron-
systems.com. During the warranty period, Omnitron will,
at its option, repair or replace a product which is proven
to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense.
Omnitron will pay the shipping charge to return the
product to Buyer’s designated US address using
Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects
resulting from improper or inadequate use and/or
maintenance of the equipment by Buyer, Buyer-supplied
equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including
removal of equipment cover by personnel not specifically
authorized and certified by Omnitron), or misuse, or
operating outside the environmental specification of the
product (including but not limited to voltage, ambient
temperature, radiation, unusual dust, etc.), or improper
site preparation or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.

Form: 040-06720-000 10/99